Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 57
OM-GRYPHON

BATTERY SELECTION

Battery selection is required only when the Gryphon™ M reader has an Alkaline
battery and you want to use OM-GRYPHON either for serial configuration,
software upgrades or to hold Gryphon™ M. Since this type of battery must not
be charged it is necessary to disable the OM-GRYPHON charge function by
following the procedure:
With the Gryphon™ M read the following code:
1.
The green LED on the Gryphon™ M will blink, signaling the reader
has accepted the command.
Place the reader onto the cradle within 10 seconds. The green LED
2.
turns off and a short beep is emitted.
To enable the charge function repeat step 1 and 2 substituting the "Alkaline"
code with the following one:
CAUTION
Attempts to charge Alkaline batteries could cause leakage
of liquid, generation of heat or, in extreme cases, explosion.
If using Alkaline batteries, carefully follow the procedure
above to avoid damage.
Alkaline
NiMh/NiCd
UK/US
13

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Om-gryphon series

Inhaltsverzeichnis