HEIDENHAIN IK 220 Benutzerhandbuch Seite 83

Pc-zählerkarte zum anschluss von heidenhain-messgeräten

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Param.
For-
Number
mat
7
16 bits 0 to 12: Number of interpolation bits
16 bits 0: Compensation for position value off
8
16 bits 0: Acquisition of compensation value off
9
10
16 bits 1 to 8: Number of measuring points per octant
11
16 bits 16 to 47: Time interval for timer
12
16 bits Software divider for timer,
13
16 bits 0 to 8191: Number of values per memory cycle
14
16 bits Bit 0=1 (integer 1): Enable the external latch L0
15
16 bits 1 to 48: SSI code length in bits
16
16 bits 0: No SSI parity
17
16 bits 0: SSI disable Gray-to-binary conversion
18
16 bits 0 to 20: SSI no. of leading zeros
19
16 bits 0 to 20: SSI no. of trailing zeros
1)
Parameter is without function
2)
Depending on the connected encoder
(only even 16-bit values possible)
3)
See next page
Meaning
Default value 12
The interpolation value (16-bit width, max. 12
significant bits, left-aligned) is rounded off to the
number of set bits.
1: Compensation for position value on
1: Acquisition of compensation value on
within a signal period for calculation of
compensation values
Default value 1
Default value 33 corresponds to 1 ms
Default value 1
that are saved in the internal RAM
Default value 8191
Bit 1=1 (integer 2): Enable internal time latch L0
Bit 2=1 (integer 4): Enable external latch L1
Default value 0
Default value 19
1: SSI parity (even)
2: SSI parity (even) with leading zeros
1: SSI enable Gray-to-binary conversion
Default value 0
Default value 0
Operating Parameters
3)
3)
83