Herunterladen Diese Seite drucken

Ik220Status - HEIDENHAIN IK 220 Benutzerhandbuch

Pc-zählerkarte zum anschluss von heidenhain-messgeräten

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

pData2:
Pointer to a variable in which the position value of
the falling edge is saved
pPeriod2:
Pointer to a variable in which the signal-period
value of the falling edge is saved
pIntpol2:
Pointer to a variable in which the interpolation
value of the falling edge is saved

IK220Status

Reports the status of the IK 220.
Prototype: BOOL IK220Status (USHORT Axis,
ULONG* pData);
Axis:
Number of the axis (0 to 15)
pData:
Pointer to a variable in which the status is saved.
Bit number Meaning
0
1 = Counter value latched in register 0
1
1 = Counter value latched in register 1
2
1 = Counter value latched in register 2
3
1 = EnDat call with continuous clock
4
1 = Contamination warning / error
5
1 = Counter started
6
1 = REF function active (start, stop, reset or
latch)
7
1 = Frequency exceeded
8
1 = Compensation values calculated once
9
1 = Calculation of compensation values active
10
1 = Values being latched in RAM buffer
11
12
13
14 and 15
REF status:
16 to 31
Driver Software for WINDOWS
0 = No REF traverse
1 = Waiting for 1st ref. mark
2 = Waiting for 2nd ref. mark
3 = REF traverse completed
103