IK220SetEnData

Sets the data line of the EnDat interface.
Prototype: BOOL IK220SetEnData (USHORT Axis,
BOOL State, USHORT* pStatus)
Axis:
Number of the axis (0 to 15)
State:
False (=0): Set data line to low level.
True (≠0): Set data line to high level.
pStatus:
0 = OK
1 = Error

IK220ReadEnData

Reads the condition of the data line on the EnDat interface.
Prototype: BOOL IK220ReadEnData (USHORT Axis,
BOOL* pState)
Axis:
Number of the axis (0 to 15)
pState:
Pointer to a variable in which the level of the
EnDat data line is saved
False (=0): Data line is on low level.
True (≠0): Data line is on high level.