MODELS
DIMENSIONS
cm
POWER SUPPLY
MAXIMUM ABSORPTION
MAXIMUM POWER
POWER SUPPLY CABLE
POWER SUPPLY
MAXIMUM ABSORPTION
MAXIMUM POWER
POWER SUPPLY CABLE
POWER SUPPLY
MAXIMUM ABSORPTION
MAXIMUM POWER
POWER SUPPLY CABLE
The data plate is on the back panel (see diagram in electric connection item) and has all the data necessary for the
connection.
When fitting, the appliance must be levelled using a spirit level; slight differences of level can be adjusted by screwing
or unscrewing the adjustable feet. The main switch or the socket must be near the appliance and easily accessibile.
It is advisable to place the appliance under an extractor hood so that steam is extracted rapidly. If the appliance is placed
near walls, dividing panels, kitchen furniture, decorative finishings, etc., these should be in flameproof material;
otherwise it is necessary to cover them with non-flammable material.
Above all, it is necessary to ensure that the fire prevention norms are observed.
Installation must be carried out observing the following norms:
- Safety prescription in force
- Installation prescription, ECI norms.
The installation, starting up and maintenance of the appliance must be carried out by qualified personnel. All operations
done when installing must be carried out observing the norms in force.
The manufacturer declines all responsibility in the event of incorrect functioning due to wrong installation or
installation which does not comply with the norms.
Attention! In accordance with international rules, when connecting the appliance, an automatic device enabling the
disconnection of all contacts from the mains, must be installed above it; this device must have a contacts opening of at
least 3 mm.
GB

TECHNICAL DATA TABLE

PCCD-64ET
400V 2N 50/60Hz 400V 3N 50/60Hz 400V 2N 50/60Hz 400V 3N 50/60Hz
10,9 A
5 kW
4x1,5 mm²
TRANSFORMATION
230Vac3 50/60Hz 230Vac3 50/60Hz 230Vac3 50/60 Hz 230Vac3 50/60 Hz
18,83 A
5 kW
4 x 2,5
mm²
230Vac 50/60Hz
21,74 A
5 kW
3 x 2,5
mm²

INSTRUCTIONS FOR INSTALLATION

INSTALLATION

LAWS, TECHNICAL RULES AND NORMS

interruzione pagina
IE
PCCD-68ET
PCCD-84ET
14,78 A
21,7 A
6,8 kW
10 kW
5x2,5 mm²
4x1,5 mm²
28,76 A
25,6 A
10 kW
6,8 kW
4 x 4 mm²
4 x 4
mm²
230Vac 50/60Hz
29,57 A
6,8 kW
3 x 4 mm²
18
PCCD-88ET
29,57 A
13,6 kW
5x2,5 mm²
39,11 A
13,6 kW
4x6 mm²