2.4
Product Specification
Model
Acting Type
Input Signal
Min. Current Signal
Supply Pressure
Stroke
Impedance
Air Connection
Gauge Connection
Conduit Entry
Protection Grade
Explosion Proof
Ambient Temp.
Linearity
Hysteresis
Sensitivity
Repeatability
Flow Capacity
Air Consumption
Output Characteristic
Vibration
Humidity
Feedback Signal
Material
Weight
Painting
Tested under ambient temperature of 20'C, absolute pressure of 760mmHg, and humidity of 65%.
SR-3300
Single
4~20mA DC
3.2mA
1.4~7 bar
10~150 mm
Max.450Ω @ 20mA DC
PT, NPT 1/4
PT, NPT 1/8
PF(G) 1/2
IP66
Ex ia IIC T6 / T5
Operating Temp. :-30~85℃
±0.5% F.S. (cable length: 5 m)
0.5% F.S.(cable length: 5 m)
±0.2% F.S (cable length: 5 m)
±0.3% F.S.(cable length: 5 m)
70 LPM (Sup.=0.14 MPa)
Below 2 LPM (sup = 0.14 MPa), Below 3 LPM (sup = 0.7MPa)
Linear, Quick Open, EQ%, User Set (16 point)
No Resonance up to 100Hz @ 6G
5-95% RH @ 40℃
4~20mA (DC 10~30V)
Aluminum Diecasting
2.0kg
Epoxy Powder Coating