Boiler output setting
To reset the temperature of the boiler OUTPUT water, proceed
as follows: from the HOME screen, press any key and then the
menu key, select BOILER and confi rm the selection
with the enter key
.:
C O N S O L E
B O I L E R
C A L D A I A
ESC
Go to the BOILER STATUS screen, press the key once, go to
the SET BOILER screen, set the SET at the desired value using
the + and - keys, the temperature can be set from a minimum of
50°C to a maximum of 80°C.
S E T B O I L E R = 6 5
S E T
C A L D A I A
6 5 °
ESC
Press the
key to move to the next setting, press the ESC key
repeatedly to return to the HOME screen.
Boiler activation/deactivation
Navigating around the boiler menu with the
BOILER PELLET menu can be found; this setting is used if
the boiler is part of a DOMOKLIMA home automation system,
otherwise the factory setting must be maintained: ACTIVE
P E L L E T B O I L E R
C A L D A I A
A T T I V A
A C T I V E
ESC
INSTRUCTIONS FOR USE
=
key, the
P E L L E T
=
THE ELECTRONIC CIRCULATOR
The product you have purchased is equipped with a circu-
lator with electronic motor.
Electronic control of operation:
a) Control mode p – c
In this mode, the electronic controller keeps the differential
pressure generated by the pump at a constant set value of H s.
Pressure differential
b) Control mode p – v
In this mode, the electronic controller varies the pressure
differential between the set value Hs and 1/2 H s. The pressure
differential varies with the volume fl ow.
Pressure differential
c) Venting procedure
This procedure allows the expulsion of air present in the
hydraulic circuit. After manual selection of the "AIR" mode,
the pump will automatically alternate between maximum and
minimum speed for 10 minutes. At the end of the procedure,
the circulator will go to the pre-set speed. You can then select
the desired mode of operation