The boiler is fuelled by pellets. These are little, cylindrical
shapes of pressed wood whose combustion is controlled elec-
tronically.
The fuel tank (A) is located at the rear of the boiler. Filling the
tank is through the back of the lid at the rear of the top.
The fuel (pellets) is taken from the tank (A) and, by means of a
screw (B) operated by a gear motor (C), is sent to the combus-
tion chamber (D).
The ignition of the pellet is via air heated by an electrical he-
ating element (E) and is sucked into the crucible by a smoke
extractor (F)
The combustion air is drawn into the room (where there must
be an air intake) smoke extractor (F).
The smoke produced by combustion, is extracted from the
thermo-stoves through the smoke extractor (F), and expelled
from the pipe union (G) located in the bottom portion of the
rear of the boiler.
The fi replace in steel, with base and ceiling in Vermiculite, is
closed at the front by a blind door.
The door has an inspection window to check on the fl ame.
The ash falls under and beside the crucible in which is housed
an ash tray from which the ash must be periodically removed
by vacuuming when cool.
The entire boiler and door are insulated which makes it more
effi cient so that the water hot water produced by the boiler is
not dissipated in the place of installation but is conveyed only
to the hydraulic system.
The boiler is designed to function with closed expansion tank
(I) and pressure valve, both of which are built in.
A hydraulic kit (P) is positioned to the side, composed of: cir-
culator, safety valve, expansion tank.
Fuel quantity, smoke extraction/combustion air supply and
pump activation are regulated by the control board which is
equipped with Leonardo
®
software to achieve high combustion
effi ciency and low emissions.
It also has a two-pole socket to connect an external graphic
panel (provided) and/or the Domoklima (the Edilkamin inte-
grated control unit).
The synoptic panel (L) which allows managing and viewing all
the operating phases, is installed on the door.
A serial port is found at the back of the boliler (cable: code
640560) to be connected to devices that allow remote ignition
(e.g. remote telephone, local thermostat).
Operating modes
(for further details, please see page 44)
The temperature of the water required in the system is set via
the panel (standard recommendation 70° C) and the boiler
manually or automatically modulates the power to maintain or
reach this temperature.
The Eco function can be enabled in small systems (the boiler
shuts down and goes on again according to the water tempera-
ture required).
FEATURES
L
D
F
LEONARDO SYSTEM
LEONARDO
allows optimal performance in all conditions thanks to two sen-
sors measuring the pressure level in the combustion chamber
and smoke temperature. The detection of and subsequent opti-
misation of these two parameters is continuous in order to cor-
rect operation anomalies in real time. The LEONARDO
offers constant combustion, automatically regulating the draft
based on the characteristics of the chimney fl ue (bends, length,
shape, diameter, etc..) and environmental conditions (wind, hu-
midity, atmospheric pressure, installations at high altitude, etc.).
The standards for installation must be respected. LEONARDO
system is also able to recognise the type of pellets and automa-
tically djust the fl ow moment by moment to ensure the required
level of combustion.

SERIAL PORT

The Dealer can install an optional on the AUX (located on the
electronic board), outlet for controlling the process of switching
on and off (e.g. telephone remote, local thermostat), located at
the rear oh the boiler.
Can be connected via special trestle (code 640560).

BACKUP BATTERY

A backup battery is found on the control board (3-Volt CR 2032
battery). Its malfunction is indicated with the following messa-
ges: (not considered a defect but due to normal wear-and-tear):
"Bat. 1".
For more detailed information, please contact the DEALER who
has performed the fi rst 1st ignition.
FUSE * the socket with a switch
on the back of the boiler has two
fuses, one inserted and a spare.
- 32
-
I
®
®
is a combustion safety and control system which
A
B
E
C
G
P
®
system
®
* *