12. You can set up operation time of the unit.
Press the (6) "SETUP" button several times
until the flashing indication "Timer" (32)
appears on the display (1). Press the (5)
button to set the required operation time of
the humidifier from
13. To learn the remaining operation time of the
humidifier, press the (6) "SETUP" button until
the flashing indication "Timer" (32) appears
on the display (1).
10. After you set the value of the relative humidity
and operation time of the humidifier, values
of the real room humidity, preset humidity
and the remaining operation time of the unit
will be displayed during 40 seconds in turns.
11.
After operation, switch off the unit, by
pressing the (3) "ON/OFF"
digital value of the relative room humidity will
appear on the display (1), and the water tank
lighting (9) will be on.
11. When the water tank becomes empty (15),
the humidifier will switch off automatically,
the indication (27) will light up on the display
(1) and you will hear sound signals.
Remote control (19)
For convenient control of the unit, use the re-
mote control. The functions of the buttons are
given in the "DESCRIPTION" section.
-
If there is an isolation insert in the battery
compartment, remove it, if the battery is
supplied separately, remove the holder of
the battery, by preliminary pressing the
clamp, insert the battery in the holder, strictly
following the polarity, insert the battery
holder into the remote control.
Cleaning and care
Warning: Always switch off and unplug the unit
before cleaning.
- Hard water causes the appearance of scale
on the "sprayer" (10), on the inner parts of the
body and on the water tank; it leads to improper
operation of the unit and appearance of white
deposit on the interior. Filter-cartridge (17)
decreases water hardness, but when using
the humidifier in regions with hard water, we
recommend using cold boiled or distilled water.
- To preserve the humidifier in good operating
condition it is necessary to clean the "sprayer"
VT 1762_Instr.indd 6
VT 1762_Instr.indd 6
"+/"
1 till12 hours.
button, the
(10) weekly and change water as often as
possible,
as well as to perform cleaning of the
filter-cartridge
(17).
-
If you are not going to use the unit for a long
time: - pour out water from the tank (15) and
the operating chamber of the "sprayer"(10),
wash the water tank (15), wash and clean the
operating chamber of the "sprayer" and the
"sprayer" (10) itself, dry the unit and take it
away for storage.
Weekly care
-
Once a week carefully wash the water tank
(15) and the operating chamber of the
"sprayer" (10) with a neutral washing liquid
solution. After that, carefully rinse them with
water.
-
Add 5-10 drops of the cleaning agent on the
"sprayer" (10); wait about 2-5 minutes. Use
a soft cloth to remove the deposit from the
surface of the "sprayer" (10).
Note:
-
As a cleaning agent for the "sprayer" (10)
you can use substances for scale removal in
kettles.
-
Do not immerse the unit into water or other
liquids.
Cleaning the filter
-
Clean the filter (17) after about 1000 l of
water pass through it, and when using hard
water or appearance of white deposit on the
furniture, more often.
-
Take the handle (12) and remove the water
tank (15) from the body (8).
-
Turn over the water tank (15), unscrew the lid
(18) by turning it anti clockwise and remove
the filter-cartridge (17), by turning it anti
clockwise.
-
Put the filter-cartridge (17) for 10 minutes
into the bowl with vinegar, take out the
filter-cartridge (17) and wash it under warm
tapping water.
-
Place the filter-cartridge (17) back on the lid
(18), by turning it clockwise.
Storage
- If you are not going to use the unit for a long
time, make sure that all its parts are dry, includ-
6
22.06.2011 17:22:57
22.06.2011 17:22:57

Werbung

loading