USER INSTRUCTIONS
Please read these instructions in conjunction with the 3M 700 Series Reference leaflet where you
will find information on: -
• Approved combinations of air filter units (AFU's) and regulators
• Spare parts
• Repair kits
• Accessories
UNPACKING
a) HT-701 Headtop
HT-702 Headtop
HT-705 Headtop
HT-748 Headtop
HT-749 Headtop
b) User Instructions
c) Reference Leaflet
d) Visor Chemical Compatibility Guide
FOREWORD
Failure to follow all instructions on the use of this product and/or failure to wear the respirator system
during all times of exposure may adversely affect the wearer's health, may lead to severe illness or
permanent disability and may render any warranty null and void.
If you have any doubts about the suitability of the product to your job situation, it is recommended that you consult
an occupational hygienist, or call 3M OH&ES Technical Affairs at your local 3M office. See back of this booklet
for addresses and telephone numbers.
SYSTEM DESCRIPTION
The 700 Series headtops combine head, eye and respiratory protection (also welding for HT-748 and HT-749) and
are designed to be used with an approved air filter unit (AFU) or regulator (see Reference leaflet) to form a
respiratory protection device.
The air will be fed via a breathing tube from a belt mounted AFU or regulator to the back of the headtop. The air
flows over the top of the wearer's head and down in front of the face. The visor and combined head and face seal
prevent the ingress of contaminated air.
APPROVALS
These products, when used as part of a 3M Approved System have been shown to meet the Basic Safety
Requirements under Article 10 and 11B of the European Directive 89/686/EEC and are thus CE marked.
The products were examined at the design stage by: British Standards Institution, 389 Chiswick High Road,
London, England W4 4AL (Notified Body number 0086).
LIMITATIONS OF USE
Use this respirator system strictly in accordance with all instructions:
• contained in this booklet,
• accompanying other components of the system (e.g. 3M 700 Series Reference leaflet, Air filter Unit or Regulator
User Instructions)
Do not use in concentrations of contaminant above 20 times the Occupational Exposure Limit (OEL).
Do not use for respiratory protection against unknown atmospheric contaminants or when concentrations of
contaminants are unknown or immediately dangerous to life or health (IDLH), or in atmospheres containing less
than 19,5% oxygen (3M definition. Individual countries may apply their own limits on oxygen deficiency. Please
seek advice if in doubt).
Only use with the Air filter units / Regulators and spares / accessories listed in the Reference leaflet and within the
usage conditions given in the Technical Specification.
Only for use by trained competent personnel.
Leave the contaminated area immediately if:
a) Any part of the system becomes damaged.
b) Airflow into the headtop decreases or stops.
c) Breathing becomes difficult.
d) Dizziness or other distress occurs.
e) You taste or smell contaminants or an irritation occurs.
061-00-82P or
061-00-83P or
061-00-84P or
061-00-85P or
061-00-86P
611-12-33
611-12-40
532-20-24
5
Never modify or alter this product, replace parts only with original 3M parts.
GB
IRL
Do not use oxygen or oxygen enriched air.
Do not use in flammable or explosive atmospheres (Call 3M OH&ES Technical Affairs at your local 3M office).
If using in Supplied Air mode ensure that:
• The source of the air supply is known;
• The purity of the air supply is known;
• The air supply is of a breathable quality, to EN12021 (UK customers use BS4275).
Only suitable for use by clean-shaven personnel, facial hair under the seal reduces protection.
Use only with recommended spectacles. Contact your supplier.
High winds above 2m/s, or very high work rates (where the pressure within the headtop can become negative) can
reduce protection. Adjust equipment as appropriate or consider an alternative form of respiratory protective device.
Materials which may come into contact with the wearers skin are not known to cause allergic reactions to the
majority of individuals.
These products contain no components made from natural rubber latex.
EQUIPMENT MARKING
For air filter unit / regulator marking please see appropriate User Instruction.
The 700 Series headtops are marked to EN1835 LDH2, prEN146 (rev) TH2.
The 700 Series headtops are marked to EN397.
The 700 Series visors are marked to EN166. Polycarbonate EN166:2:B:3 Optional visors –
Please see Reference leaflet.
The 700 Series visor surrounds are marked to EN166:3:9:-B.
The HT-748 and HT-749 welding shields are marked to BS1542 class 4.
Label inside the headtop with a date of manufacture.
Label inside the headtop: WARNING! Possible electrostatic hazard. The helmet and visor must only be cleaned in
a safe area.
PREPARATION FOR USE
Check apparatus is complete, undamaged and correctly assembled, any damaged or defective parts must be replaced
before use.
Undertake pre-use checks on air filter unit or regulator assembly as outlined in the appropriate user instruction.
For HT-748 and HT-749, insert an appropriate welding filter to EN169 and cover lenses (if applicable) –
See Technical Specification and Reference leaflet for details
Headtop adjustment
The headtop should be adjusted to give the best face seal and field of vision.
The headtop can be adjusted as shown in Fig 1.
OPERATING INSTRUCTIONS
DONNING
1. Select an approved breathing tube (Please see 700 Series Reference leaflet for list of 3M approved breathing
tubes) and connect top end to the headtop assembly.
2. Connect the bottom end of the breathing tube to the outlet of the regulator / air filter unit.
3. Adjust and fit the air filter unit / regulator as outlined in the appropriate User Instruction.
4. Ensure the visor is in the raised position and fit headtop. Ensure headtop is held firm and comfortable.
If necessary adjust headtop as described earlier.
5. Switch on the air filter unit or connect the compressed air supply tube to the regulator
6. Grip face seal loop and pull visor down into the lowered position, at the same time position the bottom of the
face seal under the chin. Ensure visor-retaining stud is fully engaged. Check face seal is correctly positioned all
around the face and back of the head.
7. Ensure at least minimum airflow into the headtop is achieved and adjust for maximum comfort – see appropriate
User Instruction.
IN USE
Use in the power / air supply off state is not normal, little or no protection is provided, vacate the
contaminated area immediately.
Take care to prevent the breathing tube from becoming looped around protruding objects.
Do not remove the headtop, switch off the air filter unit or turn off the air supply until you have vacated the
contaminated area.
If during use the air supply stops or is reduced, vacate the contaminated area immediately and investigate the cause.
6