Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting - Velleman SG21000 Bedienungsanleitung

Drahtloses alarmsystem
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

10. Door/Window Sensor (order code HAM1000WS/SDWS, optional)
a. Testing the System
Before mounting, it is recommended to test the transmitting range. Press HOME on the main, wait 60 seconds,
open and close the magnetic switch of the door/window sensor to trigger the alarm. Deploy the aerial if necessary.
b. Installation
1. Open the battery cover and install 1 x 9V battery (order code 6LR61, not incl.). Close the battery cover.
2. Choose a mounting location to mount the sensor. Fix the sensor to the door or window frame using the
included double-sided tape. Make sure to align both marks ( and ).
3. It is possible to add extra wired magnetic sensors in order to expand the detection area.
• Open the battery compartment of the door/window sensor.
• Remove the screw from the terminals and remove the connection wire.
• Measure the length of the wire needed to connect the sensor to the transmitter and cut the wire at the
correct length. Strip 1.5cm (± ½") of insulation from the wire
ends and twist the conductor wires together.
• Connect the sensor with the transmitter. Make sure to connect
the sensor and the transmitter in a loop. Connect in series
when using more than one sensor (see fig.).
c. Operation
The unit will switch to standby 60 seconds after battery installation.
11. Door/Window Sensor with Alarm (order code HAM1000WS/DWS, optional)
a. Testing the Door/Window Sensor
Before mounting, it is recommended to test the transmitting range. Press HOME on the main, wait 60 seconds,
open and close the magnetic switch of the door/window sensor to trigger the alarm. Deploy the aerial if necessary.
b. Installation
1. Unscrew and remove the battery cover. Install 1 x 9V battery (order code 6LR61, not incl.). Close the battery
cover.
2. Choose a mounting location to mount the sensor. Drill the holes
and insert the plugs and screws. Fix the sensor onto the screws.
3. Now, mount the magnetic sensors to the door or window frame
using the included double-sided tape. Make sure to align both
marks ( and ).
4. Connect the sensor with the transmitter. Connect in series when
using more than one sensor (see fig.).

12. Troubleshooting

Problem
Main unit will not arm / disarm
No remote control function
HAM1000WS_v3
Possible Solution
• Make sure you've entered the correct access code. If not, re-enter the code.
• Reset (
) the main unit using a sharp object and try to arm/disarm again.
• Check the battery and replace if necessary.
• Reprogram the ID code (see "5.b. ID Codes")
7
VELLEMAN

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis