2. GETTING STARTED
To get started with the SMS-Alert at least the following steps need to be taken in following order:
1. Place SIM card (with PIN code 0000 or without PIN code) (See text about SIM at section " Attention")
2. Connect the inputs
3. Place the batteries
4. Connect the unit to the external power supply
5. Program at least one telephone number (administrators' number)
6. Arming/disarming the system
These steps are further explained in this chapter. After these steps the module will be operational.
2.1 PLACE A SIM CARD
Open the enclosure with the 4 screws and insert a SIM card into the module. Push the black cover outward slightly to open the holder. Before installing the SIM card should
have PIN code " 0000", or be free of a PIN code.
(A PIN code can be changed or removed by putting the SIM card in a mobile phone and change or remove the PIN in the security menu.)
NB: make sure the SIM card is inserted before the batteries are placed. In case of a SIM card change, please first remove the batteries (and remove any other external power
supply).
2.2 CONNECT THE INPUTS
It is possible to connect external sensors to the inputs. As a standard reaction after a triggered input, the SMS-Alert sends an SMS text message to the preset numbers and
calls these numbers.
Insert the 2 wires of an external sensor through the hole of the enclosure to the inside part and next in the two connectors of input 1. It does not matter which wire is con-
nected to which connector. If necessary the wires can be extended up to 5 meters using appropriate wire material.
When using a second input, connect this to input 2. In that case you will need an extra hole in the control cabinet that can be made with an " 8 mm" drill. In the packaging of
the device you will find an additional small O-ring where the cable can go through.
As default the inputs are programmed as Normally Closed (NC) contacts. This means the inputs are triggered in case the input is opened during at least the delay time. In case
the contact should be Normally Open (NO), please refer to paragraph 3.4.5. For the delay time, please refer to 4.4.6.
2.3 PLACE THE BATTERIES
Place the two batteries (CR123) in the module. Use the +/- indication for the correct placement. The green LED will flash to indicate that the module is not configured (at
least 1 telephone number should be programmed).
2.4 CONNECT THE UNIT TO THE EXTERNAL POWER SUPPLY
Connect the external power adapter (or any other regulated 12VDC power supply) to the power input of the connector:
• V+ (black lead with white stripe) to " +"
• Ground (black lead) to " -"
As soon as the power supply is connected, the module searches for GSM network connection; during this time the LED outside is flashing. As soon as network connection is
established, the LED will be ' on' .
2.5 PROGRAM AT LEAST ONE TELEPHONE NUMBER
The SMS-Alert is able to send messages up to 5 telephone numbers. The first telephone number belongs to the administrator. Technical messages (like " battery low") are sent
to the administrator only. Without the administrators' phone number, the SMS-Alert cannot not function.
When the SMS-Alert is in initial (factory) status and power supply is connected (so the LED is 'on'), the administrators' number is programmed by calling the telephone
number of the SMS-Alert using the administrators' phone. The unit will recognize this number and store it as administrator (telephone number 1). The administrator will
receive a confirmation SMS text message including the security code. This code is needed to program the other settings in the unit.
NB: for this way of programming the number recognition in the administrator's phone must be 'on' . To program or change the administrators' number by SMS command,
please refer to 3.4.1.
2.6 SWITCHING ON/OFF
After the previous steps, the SMS-Alert is ready for use.
It is armed (switched on) automatically. The green LED blinks once in 3 seconds.
In order to switch off (disarm) the SMS-Alert:
• Press the on/ off button at the upper side for 1 second.
The green LED switches off to indicate the armed status.
In order to switch on (arm) the SMS-Alert:
• Press the on/ off button at the upper side for 1 second.
The green LED blinks once in 3 seconds (or permanently in case of an external power supply) to indicate the armed status.
6
3. EXTENDED OPTIONS
To program the SMS-Alert, the GSM module must have network connection. The configuration is programmed by SMS messages.
All settings are stored and will be kept in the unit, even in case the power supplies are removed.
3.1 PROGRAM MODE
As long as the SMS-Alert has external power supply, it has GSM network connection. The module is ready to receive SMS commands. In case the SMS-Alert has no external
power supply but is fed by batteries, the module enters the program mode directly after placing the batteries. During the time the module searches GSM network connection
the LED flashes 2 sec. on/1 sec. off. Within 10-30 seconds the connection is established and the status LED starts flashing 1 sec. on/1 sec. on (or ' off' in case the first telephone
number has not been configured).
The SMS-Alert (just fed by batteries) returns to the program mode by pressing the on/off button during 5 seconds, until the LED starts flashing (or turns to ' on').
3.2 THE SECURITY CODE
For configuration activities the security code of the SMS-Alert must be used. The initial security code is ' 1111' .
As soon as the security code is changed, the new code is sent in a confirmation SMS message to the administrator (first telephone number).
<CODE>
In this manual this code is referred to as
.
3.3 PROGRAMMING THE SETTINGS BY SMS
You should not type the "<" and ">" characters in the text of the SMS commands!
The settings are programmed by SMS text messages.
• Be sure the SMS-Alert is in program mode (please refer to 4.1).
• Send an SMS message with following content:
<CODE> <command>
• Do not forget the space character between <PIN code> and <command>.
• The commands are case sensitive.
• Several commands may be combined in one SMS message (with a maximum of 160 characters) by placing a # between the commands.
<CODE> <command1>#<command2> ...... #<commandN>
The green LED blinks 3 times to indicate the successful configuration. In case of an incorrect command, the LED flashes 5 times.
In 4.5 the complete scheme with SMS commands is listed
3.4 POSSIBLE GENERAL SETTINGS
This paragraph describes the general settings for the SMS-Alert.
3.4.1 Phone numbers
The SMS-Alert is able to send alarm messages up to 5 phone numbers. The first telephone number (TEL1) belongs to the administrator. Only this number receives all system
messages. The other phone numbers (including the administrator) only get the alarm messages.
To set or change telephone numbers:
<CODE> TEL1:<telephone number>
SMS command 1st telephone number:
<CODE> TEL2:<telephone number>
SMS command 2nd telephone number:
.... similar for TEL3...TEL5
To delete telephone numbers:
<CODE> DEL1
SMS command delete 1st telephone number:
.... similar for DEL2...DEL5
In case a foreign number needs to be entered start with 00 follow by the country code (e.g. 0031612345678).
3.4.2 Identification text
It is possible to add a standard identification text (NAME) to all messages sent out by the SMS-Alert. The alarm messages are a combination of the name and the alarm text.
A user defined identification has a length of maximum 20 characters. The default identification text is ' SMS alert.
<CODE> NAME:<free text>
SMS command identification text:
3.4.3 Alarm text
Unique alarm texts can be programmed into the SMS-Alert. User defined texts have a maximum length of 20 characters.
Following default texts are programmed: