Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Specifications - Lincoln Electric LINC 405 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für LINC 405:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 12
Input and output cables, control cables, and telephone cables that are in or adjacent to the work area and the
machine.
Radio and/or television transmitters and receivers. Computers or computer controlled equipment.
Safety and control equipment for industrial processes. Equipment for calibration and measurement.
Personal medical devices like pacemakers and hearing aids.
Check the electromagnetic immunity for equipment operating in or near the work area. The operator must be sure
that all equipment in the area is compatible. This may require additional protection measures.
The dimensions of the work area to consider will depend on the construction of the area and other activities that are
taking place.
Consider the following guidelines to reduce electromagnetic emissions from the machine.
Connect the machine to the input supply according to this manual. If disturbances occur if may be necessary to take
additional precautions such as filtering the input supply.
The output cables should be kept as short as possible and should be positioned together. If possible connect the
work piece to ground in order to reduce the electromagnetic emissions. The operator must check that connecting
the work piece to ground does not cause problems or unsafe operating conditions for personnel and equipment.
Shielding of cables in the work area can reduce electromagnetic emissions. This may be necessary for special
applications.

Technical Specifications

Input Voltage
230 / 400V
Three Phase
Duty Cycle
(Based on a 10 min. period)
35%
60%
100%
Welding Current Range
15 – 400 Amps
Fuse or Circuit Breaker Size
63A Superlag (230V input)
40A Superlag (400V input)
Height
640 mm
Operating Temperature
–10°C to +40°C
For any maintenance or repair operations it is recommended to contact the nearest technical service center or Lincoln
Electric. Maintenance or repairs performed by unauthorized service centers or personnel will null and void the
manufacturers warranty.
Input Power at Rated Output
10%
34 kVA @ 35% Duty Cycle
RATED OUTPUT AT 40°C
RECOMMENDED INPUT CABLE AND FUSE SIZES
PHYSICAL DIMENSIONS
Width
580 mm
INPUT
Output Current
400A
315A
240A
OUTPUT RANGE
Maximum Open Circuit Voltage
Length
1150 mm
(700 mm without handles)
7
Frequency
50 Hertz (Hz)
Output Voltage
36.0 Vdc
33.0 Vdc
29.0 Vdc
78 Vdc
Input Power Cable
2
4 Conductor, 6 mm
Weight
126 Kg
Storage Temperature
-25°C to +55°C

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis