Herunterladen Inhalt Inhalt Diese Seite drucken

Electromagnetic Compatibility (Emc) - Lincoln Electric LINC 405 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für LINC 405:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 12
4.
Hot Start Control (LINC 405-SA only): Hot Start is a
temporary increase in the output current during the
start of stick (MMA) weld that helps ignite the arc
quickly and reliably. It allows to adjust level of
current increasing.
5.
Negative Quick Disconnect: Negative output
connector for the welding circuit.
6.
Digital Welding Current Meter with memory feature
(LINC 405-SA only): Shows present value of the
welding current during welding; after welding it holds
reading of average value of the welding current from
the last 2 seconds.
7.
Output Current Control: Potentiometer used to set
the output current (also during welding), from 15A to
400A.
8.
Local/Remote Switch: Remote Control Unit
K10095-1-10 can be used with this machine.
9.
Arc Force Control (LINC 405-SA only): It is a
function used during stick (MMA) welding in which
the output current is temporarily increased to clear
short circuit connections between the electrode and
the weld puddle that occur during normal welding.
10. Remote Control Connection: If a remote control is
used, it will be connected to the remote connector.
11. Positive Quick Disconnect: Positive output
connector for the welding circuit.

Electromagnetic Compatibility (EMC)

This machine has been designed in accordance with all relative directives and norms. However, it may still generate
electromagnetic disturbances that can affect other systems like telecommunications (telephone, radio, and television) or
other safety systems. These disturbances can cause safety problems in the affected systems. Read and understand
this section to eliminate or reduce the amount of electromagnetic disturbance generated by this machine.
This machine has been designed to operate in an industrial area. To operate in a domestic area it is
necessary to observe particular precautions to eliminate possible electromagnetic disturbances. The
operator must install and operate this equipment as described in this manual. If any electromagnetic
disturbances are detected the operator must put in place corrective actions to eliminate these disturbances
with, if necessary, assistance from Lincoln Electric.
Before installing the machine, the operator must check the work area for any devices that may malfunction because of
electromagnetic disturbances. Consider the following.
12. Fuse: This fuse protect the Fan Circuit.
13. Power Input Socket: Connect supply plug to the
existing input cable, which is appropriate to rating of
the machine indicated in this manual and in
conformity with obligatory standards. The
connecting should be made by an entitled person.
Stick Welding (MMA)
For starting welding process with MMA method you
should:
Insert current cables plugs to appropriate sockets
and block them there.
Connect the work cable to the welding piece with the
work clamp.
Fasten a correct coated electrode into the electrode
holder.
Connect the mains plug to the outlet mains socket.
Set the Local/Remote Switch in required position:
local or remote.
Turn the Power on/off Switch on.
Set required welding current by knob of the Output
Current Control.
Obeying appropriate rules you can begin to weld.
6
02/02

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis