Herunterladen Inhalt Inhalt Diese Seite drucken

Manual Roldeck Operation - STARLINE ROLDECK Anleitung

Vorschau ausblenden Andere Handbücher für ROLDECK:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

7.4 Manual Roldeck Operation

If the Roldeck motor fails due to a malfunction
with one of the sensors (error code is readable
in LED display or s switch).
The function of the sensor can be switched off
by means of a button combination together
with the jumper.
First turn on the Roldeck Control by means
of the red button (1) and connect the
jumper of the RD2013 into socket (2).
Than push the buttons "prog" and "mode"
simultaneously for 3 seconds in a row.
The manual Roldeck Control function
is only meant in case of need, by using
this control the pre-programmed OPEN
and CLOSE position will be erased from
the memory of the Roldeck Control unit.
After the problems are solved the OPEN
and CLOSE position must be programmed
again.
Subsequently the Roldeck can be
controlled manually by pushing the "open"
and "close" button in the control box until
the desired position is reached.
When the button is released, the Roldeck
stops automatically. Pay attention when
opening or closing the Roldeck that the
Roldeck doesn't move too far.
30
User manual Starline Roldeck
1.
RDCM V03-1015
3,15A/T
2.
S202
S200
S203
S201
Open
Prog.
Close
Mode
S202
S200
S203
S201
Open
Prog.
Close
Mode
OR
3 sec.

Quicklinks ausblenden: