Herunterladen Inhalt Inhalt Diese Seite drucken

Failures; Overview Failure Messages Rdeb2013 - STARLINE ROLDECK Anleitung

Vorschau ausblenden Andere Handbücher für ROLDECK:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

7

Failures

7.1 Overview failure Messages RDEB2013

Consult the failure table below in cause of a display error.
Contact the installer if necessary.
Display Error Description
F01
No sensor signal by start motor
No sensor signal during running for ≤ 1 second
F02
F03
Wrong direction of rotation (50 pulses in the wrong direction)
F04
Short-circuit (motor current> 30A)
F05
Too much current (motor current for 10 s> 9.5 A)
F06
Runtime error (Roldeck> 900s, bottom lid > 120s)
F07
Overvoltage (motor voltage for 5s> 45V)
F09
Overtemperature chopper module (temp> 100 ° C)
F10
Sensor short circuit (sensor inputs A & B)
F11
Sensor error (both sensors are different)
F12
Absolute overvoltage (motor voltage> 60V)
F21
Water Level Sensor Input Open (RD Model: SK)
F22
Key switch off "0"
F31
Under pressure Roldeck driver, low pressure in in-roller motor Roldeck
F32
Under pressure liddriver, low pressure in in-roller motor of moveable bottom flap
For error F04, F11 and F12: switch control off
User manual Starline Roldeck
RDCM V03-1015
27

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading