Herunterladen Inhalt Inhalt Diese Seite drucken

Denervated Programme - CefarCompex Physio 5 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für Physio 5:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 37
the large (red) Iontophoresis electrodes
supplied with the stimulator.
The Hyperhidrosis programme is in the
Direct Current category of the Specific
Treatment type.
18a
18b
18a: Press the On/Off button to return to
the previous screen.
18b: Use the channel 1 +/- button to
choose a programme.
18e: Press the channel 4 +/- button to
confirm your choice.
19a
19c
19a: Press the On/Off button to return to
the previous screen.
19c: Use the channel 2 +/- button to
change the default electrical density value.
19e: Press the channel 4 +/- button
to confirm your choices and access a
confirmation screen.
Use the i button to access the electrodes
placement pictogram.
The Hyperhidrosis programme lasts for 12
minutes and can only be run on channel
1. Only use the red electrodes with this
programme. Other electrodes will cause
current intensity calculation errors.
20a
20a: Press the On/Off button to return to
the previous screen.
20e: Press the channel 4 +/- button
to confirm your choices and start the
programme.
Use the i button to access the electrode
placement pictogram.
NOTE: Press the i button from the
stimulation screen or the end of
programme screen to access the
programme parameters.

6 - Denervated programme

The Denervated programmes are part of
the Specific Treatment. Do not use these
programmes in the chest region.
Physio5 Denervated programmes are
18e
not contraindicated in patients with
osteosynthesis devices or other metal
implants
Denervated programmes should only
be run with 2.1 mm pin-connector
cables and carbon electrodes (black
electrodes supplied with stimulator). For
optimal results, apply conductor gel to
the electrodes before use. Do not use
snap-connector cables or selfadhesive
electrodes for Denervated programmes.
There are 2 types of Denervated
19e
treatments.
21a: Press the On/Off button to return to
the previous screen.
21b: Use the channel 1 +/- button to
choose the programme you want.
21e: Press the channel 4 +/- button to
confirm your choice.
Total manual
Full denervation programme. This
programme works with rectangular
pulses and allows the following
parameters to be modified:
• Pulse width
20e
• Period
• Programme duration
21a
21b
21e
ENG
14

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis