INSTALLATION

Note: If the unit has not been stored or move in an upright position, let it stand upright for approximately 12
hours before operation. If in doubt allow to stand.
1. Remove the appliance from the packaging and the protective film and coatings are thoroughly removed
from all surfaces.
2. When positioning the appliance, maintain a distance of 20cm (7 inches) between the appliance and
walls or other objects for ventilation. Increase this distance if the obstacle is a heat source.
Note: Before using the appliance for the first time, clean the shelves and interior with soapy water and rinse
thoroughly.

OPERATION

CONTROL PANEL
The control panel is located below the doors on the rear of the appliance.
TURN ON
1. Close the door of the appliance.
2. Connect the appliance to a mains power supply.
3. Press the button
SET THE OPERATING TEMPERATURE
1. Press the
2. Press the
3. Press the
TABLE OF CONTROLLER PARAMETERS
The operating parameters of this appliance have been preset for optimum performance and to maximize the life
of the appliance.
Display
E1
Lower set temperature
E2
Upper set temperature
E3
Temperature buffer
E4
Temperature buffer time delay
E5
Fixed parameter
E6
Foxed parameter
F1
Defrost period
F2
Defrost interval
F3
Defrost temperature
F4
Centigrade/Fahrenheit
to turn the light On or Off as required
button. The display will flash.
or
buttons to display the required temperature.
button to store the temperature.
Parameter
Preset Value
0°C
-20°C to 2°C
12°C
2°C to 45°C
4°C
1°C to 10°C
3 minutes
0 to 10 minutes
0
DO NOT CHANGE
00
DO NOT CHANGE
25 minutes
1 to 60 minutes
6 hours
1 to 24 hours
20°C
0°C to 22°C
0°C
°C/°F
Range
5