ELZI
30, 40, 60
6. Life Stages
6.3 Commissioning
Only authorized persons who have read and understood these Installation Instructions completely are allowed to take this
positioning system into operation. When this linear unit is in operation, forces arise which can lead to injuries and property
damages. It is imperative that the safety rules and limits of the linear unit are observed.
6.3.1 Normal Operation
While the linear unit is in operation, check it for correct performance of its function regularly.
During normal operation, look for any visible changes of the incomplete machine.
If defects should arise, shut down the linear unit immediately in order to avoid damage.
According to Machinery Directive 2006/42/EC, the operating instructions of the complete machine
are relevant because this incomplete machine is an element of a complete unit.
6.4 Maintenance/Repair/Cleaning
Before starting any work on the linear unit, any electrical drives must be isolated!
All linear units are provided with the required lubricant quantity in the factory.
Lubricant recommendation: see section 8.2 Lubricants
Rods will be greased by the strippers of carriage.
There are 2 oil nipples in each wiper end plate (4), where the tanks for the strippers can be filled with an oil gun.
Viscosity of oil: 200 mm²/s, T= 40° C. Interval of greasing depends on environmental conditions, min. once a month.
Minimum stroke must be same than length of slide.
4
Montageanleitung / Maschinenrichtlinie
4
Installation Instructions
24.09.2012
Seite / Page 16