Important:
The electric strike plate or lock that you install must be equipped with a mechanical memory. For
wiring, refer to the label on the back of the camera.
c. Connecting a gate motor (fig. 6)
Directly connect the gate motor wires to terminals 3 and 4 on the back of the camera. The camera provides a
'dry'-contact connection, without an electric current, to connect to the button for your automated gate.
Note that this function is only valid if the screen is on.
6. USER MANUAL
Important:
The touch-sensitive buttons must be used with fingers only.
a. Using and adjusting the videophone
Press < 1s: view intercom panel camera.
Press for 5s: access menu.
Press left arrow on menu screen.
Answer a call and talk to visitor.
Press right arrow on menu screen.
Open electric strike plate.
Press down arrow on menu screen
Open gate (dry contact)
Note that gate opening functions are only valid if the screen is on. When the opening command is
given, the video briefly cuts out.

7. TECHNICAL CHARACTERISTICS

a. Monitor
• Power supply: 17 V
• Consumption: 25.5 W
• 4" (11 cm) screen
• Resolution: 480 x 275 points
• Dimensions (mm): 153.8x125x24.4