176.0
2.0
bo_STA_WRI_PROT
176.1
2.1
bo_STA_WR_MIN
176.2
2.2
bo_STA_Reserve1
176.3
2.3
bo_STA_Reserve2
176.4
2.4
bo_STA_Reserve3
176.5
2.5
bo_STA_Reserve4
176.6
2.6
bo_STA_Reserve5
176.7
2.7
bo_STA_ERROR_ON
177.0
3.0
bo_STA_LIMIT1_ON
177.1
3.1
bo_STA_LIMIT2_ON
177.2
3.2
bo_STA_TARED
177.3
3.3
bo_STA_TARED_BY_MANUAL
177.4
3.4
bo_STA_MAX_9E
177.5
3.5
bo_STA_025_D_ZERO
177.6
3.6
bo_STA_ST_STAND_SCALE_ON
177.7
3.7
bo_STA_SCALE_CALIBRATED
178.0
4.0
b_OPR_ERR_MSG
179.0
5.0
b_Reserve
180.0
6.0
i_GROSS_WEIGHT_PROC
182.0
8.0
i_NET_WEIGHT_PROC
184.0
10.0
i_TARE_WEIGHT_PROC
186.0
12.0
i_GROSS_NET_VALUE
188.0
14.0
d_GROSS_NET_VALUE_10X
192.0
18.0
i_TARE_VALUE
194.0
20.0
i_ADC_DIGIT
196.0
22.0
i_ADC_DIGIT_FILTER
198.0
24.0
s_WEIGHT_ASCII
214.0
40.0
i_MILISEC
216.0
42.0
b_SECONDS
217.0
43.0
b_MINUTE
218.0
44.0
i_HOURS
=46
220.0
220.0
i_DB_Length1
Tabelle 8-1
Belegung des Waagen-DB für FB SICS_DR
Waagen_DB für FB SICS_BA
DB
DR
0.0
0.0
i_DB_Length
2.0
2.0
i_MaxLifeBitCyc
4.0
4.0
i_SFC_ERR_C
6.0
6.0
i_CMD_INPUT
8.0
8.0
bo_CMD_TRIGGER
8.1
8.1
bo_CMD_IN_PROGRESS
8.2
8.2
bo_CMD_FINISHED_OK
8.3
8.3
bo_CMD_ERR
8-58
SIWAREX CS
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BYTE
BYTE
INT
INT
INT
INT
DINT
INT
INT
INT
STRING[14]
INT
BYTE
BYTE
INT
END_STRUCT
INT
Name
Type
INT
INT
WORD
INT
BOOL
BOOL
BOOL
BOOL
FALSE
Status write protection on
FALSE
Status weighing range minimum
FALSE
Status reserve
FALSE
Status reserve
FALSE
Status reserve
FALSE
Status reserve
FALSE
Status reserve
FALSE
Status operational error on
FALSE
Status limit 1 is on
FALSE
Status limit 2 is on
FALSE
Status scale tarred
FALSE
Status scale tarred by manual
FALSE
Status max plus 9 e
FALSE
Status zero 0.25 d
FALSE
Status stand still 1 on
FALSE
Status scale is calibrated
B#16#0
Operation error bits
B#16#0
0
Actual weight process value gross
0
Actual weight process value net
0
Actual weight process value tare
0
Actual weight process legal value
L#0
Actual weight process legal value x 10
0
Actual weight tare process legal value
0
Actual ADC digit value before filtering
0
Actual ADC digit value after filtering
''
Actual weight as ASCII string
0
Actual runtime milliseconds
B#16#0
Actual runtime seconds
B#16#0
Actual runtime minutes
0
Actual runtime hours
222
Default
Comment
52
Length of the DB
500
Lifebit check
W#16#0
Communication error RET_VAL of sfc58/59
0
Command code input
FALSE
Command trigger
FALSE
Command in progress
FALSE
Command finished ok
FALSE
Command error length