8.2
8.2
bo_CMD_FINISHED_OK
8.3
8.3
bo_CMD_ERR
9.0
9.0
b_CMD_ERR_CODE
10.0
10.0
i_PRESET_TARE
12.0
12.0
b_SELECT_PROC_VAL
13.0
13.0
b_SELECTED_PROC_VAL
14.0
14.0
i_PROCESS_VALUE
16.0
16.0
b_INFO_REFRESH_COUNT
18.0
18.0
w_SCALE_STATUS
20.0
20.0
b_OPR_ERR_MSG
21.0
21.0
bo_FB_ERR
22.0
22.0
b_FB_ERR_CODE
23.0
23.0
bo_START_UP_IN_PROGRESS
24.0
s_CMD1
24.0
0.0
i_CMD1_Code
26.0
2.0
bo_CMD1_Trigger
26.1
2.1
bo_CMD1_InProgress
26.2
2.2
bo_CMD1_FinishedOk
26.3
2.3
bo_CMD1_FinishedError
=4
28.0
s_CMD2
28.0
0.0
i_CMD2_Code
30.0
2.0
bo_CMD2_Trigger
30.1
2.1
bo_CMD2_InProgress
30.2
2.2
bo_CMD2_FinishedOk
30.3
2.3
bo_CMD2_FinishedError
=4
32.0
s_CMD3
32.0
0.0
i_CMD3_Code
34.0
2.0
bo_CMD3_Trigger
34.1
2.1
bo_CMD3_InProgress
34.2
2.2
bo_CMD3_FinishedOk
34.3
2.3
bo_CMD3_FinishedError
=4
36.0
36.0
w_DB_RES92
38.0
38.0
w_DB_RES93
40.0
40.0
w_DB_RES94
42.0
42.0
w_DB_RES95
44.0
44.0
w_DB_RES96
46.0
46.0
w_DB_RES97
48.0
48.0
w_INT_USE
50.0
s_JUST_DAT
50.0
0.0
w_CALIB_DIGITS0
52.0
2.0
w_CALIB_DIGITS1
54.0
4.0
w_CALIB_DIGITS2
56.0
6.0
i_CALIB_WEIGHT1
58.0
8.0
i_CALIB_WEIGHT2
8-56
SIWAREX CS
BOOL
FALSE
BOOL
FALSE
BYTE
B#16#0
INT
0
BYTE
B#16#0
BYTE
B#16#0
INT
0
BYTE
B#16#0
WORD
W#16#0
BYTE
B#16#0
BOOL
FALSE
BYTE
B#16#0
BOOL
FALSE
STRUCT
INT
0
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
END_STRUCT
STRUCT
INT
0
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
END_STRUCT
STRUCT
INT
0
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
END_STRUCT
WORD
W#16#0
WORD
W#16#0
WORD
W#16#0
WORD
W#16#0
WORD
W#16#0
WORD
W#16#0
WORD
W#16#0
STRUCT
WORD
W#16#0
WORD
W#16#EA60 Calibration digits for 1
WORD
W#16#0
INT
2000
INT
0
Command finished ok
Command error length
Command error code
Preset tare value
Selection of the process value for output
Selection of the process value for output
Process value
Refresh counter info
Scale status info
Operation error bits
Error in function block length
Error code for function block
Start up of function block in progress
Command input 1
Command code
Command trigger
Command in progress
Command finished ok
Command finished with error
Command input 2
Command code
Command trigger
Command in progress
Command finished ok
Command finished with error
Command input 2
Command code
Command trigger
Command in progress
Command finished ok
Command finished with error
Word for internal use of FB SICS...
DR3: Calibration parameters
Calibration digits for 0
Calibration digits for 2
Calibration weight for 1
Calibration weight for 2

Quicklinks ausblenden: