- In order to prevent dangerous situations or malfunctioning, the electrical command
elements wired to the motor must be sized according to the motor's electrical features.
- Means for disconnection must be incorporated in the fixed wiring in accordance with
the national installation standards.
- For outdoor use, provide the appliance with a supply cable with designation H05RN-F
containing at least 2% of carbon.
- If not used, the white wire must be insulated. It is dangerous to touch the white wire
when the motor is powered.
* Optional step by
step - Switch
green-yellow
*
Installing this button is optional. The connection can be done differently using the
brown wire or the blue wire. The button affords the possibility to command the motor in
stepping mode (up, stop, down, stop, up, stop, down, stop..)