RMLT9xxx
• The outer wall must be fitted with an air inlet vent (fig. 3 1, page 4) and an outlet
vent (fig. 3 2, page 4) with ventilation grilles so that the heat generated can be
easily released to the outside:
– Air inlet vent: Fit the ventilation grille as flush as possible to the floor of the
installation niche with a minimum cross-section of 400 cm².
– Outlet vent: fit as far above the refrigerator as possible.
– The distance between the air inlet and outlet vents must be at least 1050 mm
(fig. 5, page 5).
• Fit a heat conduction plate (fig. 3 3, page 4) above the refrigerator so that the
heat does not accumulate in the vehicle.
• If the ventilation grille of the air inlet vent cannot be installed flush to the ground,
an additional inlet vent (fig. 3 6, page 4) must be provided in the floor for
releasing leaked gas.
• The distance between the top of the oven and the ceiling must be at least
170 mm (fig. 3, page 4).
• If a roof flue (fig. 3 4, page 4) is being used: Fit a detachable panel (fig. 3 5,
page 4) above the oven so that you can always reach the flue pipe.
• If you do not have a roof flue: Fit a panel with a ventilation grille (fig. 4 7, page 4)
above the oven.
• The distance between the top of the oven and the flue outlet of the roof flue must
be between 250 mm and 1500 mm (fig. 5, page 5).
• Too large a gap between the refrigerator-oven combination and rear wall leads
to poor performance and increases the power consumption of the refrigerator.
Reduce the space behind the refrigerator-oven combination to create adequate
air inlet and outlet ventilation (fig. 6, page 5).
• The refrigerator-oven combination must not be installed at the side of the air inlet
and outlet vents as this leads to poor performance and increases the power
consumption of the refrigerator.
• The air inlet and outlet vents must not be covered by vehicle parts (such as an
open door or by installing accessories such as bicycle racks) while operating.
• Install the refrigerator-oven combination so that it is protected from excessive
heat, as this leads to poor performance and increases the power consumption of
the refrigerator.
• The electrical installation must comply with national and local regulations.
European standards: EN 60335-1, EN 60335-2-24, EN 1648-1 and EN 1648-2.
• The gas installation must comply with national and local regulations.
European standard: EN 1949.