Program adjustments
Adjustment of flushing programs (only possible in the first 10 sec. after initiation):
as soon as battery or mains adaptor will be connected (program 1 factory-made
pre-adjusted)
1.
12V version: connection to power supply
6V version: insert batteries
For changing the flushing program of an already adjusted WC-control, the power sup-
ply must be disconnected (disconnect external power supply unit or remove the batte-
ries) for at least 30 sec., afterwards a new programming is possible.
2.
The device makes a selftest, then the diagnostics LED flashes 3 times quick. From
that time there are 10 sec. for adjusting the flushing program.
3.
Via close range reflex (hold hand approx. 5 cm in front of infrared window) it is now
possible to choose between 3 different programs.
*
1 slow flash = program 1 - standard program (preset)
**
2 slow flashes = program 2 - private program
***
3 slow flashes = program 3 - manual program
4.
Remove hand at the desired program, the control confirms the program by flashing
twice quickly.
5.
Afterwards there are further 10 sec. for changing the flushing program again. After
lapse of this time, the device flashes 3 times quickly and it changes into normal func-
tion.
Close range reflex:
Diagnostics LED:
flashes in the first
minute after initiation
at reflex
Additionally at batte-
ry operated variant:
LED begins to flash,
when battery becomes
empty.
13