Technical data

Problem
The display shows
"Error 10"
The display shows
"Error 11"
The display shows
"Error 12"
12
Technical data
Item number:
Dimensions (width x height x depth):
Weight:
Power supply:
Refrigerant extraction rate:
Vacuum pump output:
Hermetic compressor output:
Drier filter output:
Filling cylinder accumulator capacity:
Noise emission:
Accuracy of the electronic scale for refrigerant:
Accuracy of the electronic scale for old/new oil:
Accuracy of the electronic scale for UV additive:
Operating temperature range:
110
Cause
It was not possible to reduce
the pressure sufficiently dur-
ing the "Software test".
It was not possible to drain
any used oil during the "Soft-
ware test".
It was not possible to remove
any refrigerant from the inter-
nal tank during the "Soft-
ware test".
ASC2500
Remedy
Residual pressure on the
pressure gauges?
Check pressure transducer
calibration.
Check internal bottle
pressure.
Check the compressor and
the corresponding solenoid
valves.
Insert receptacle for drained
oil correctly. Check that the
solenoid valve can move
freely. Check that the scale is
working properly.
Check pressure transducer
calibration.
Check if the valve on the
internal tank is open. Check
the RE valve.
AirConServiceCenter
ASC2500
8885200095
560 mm x 1300 mm x 650 mm
100 kg
230 V/240 V – 50 Hz/60 Hz
30 kg / h
5 cars / h
0.32 kW
150 kg
16 kg
55.5 dB (A)
± 10 g
± 1 g
± 1 g
+ 5 °C to + 50 °C