G B
I E
compliant with the safety regula-
tions of the energy supply com-
pany and function without fault,
- The protection of the electrical
plug connections from the wet.
• Ensure that the mains voltage
the rating plate.
• The electrical installation shall be
according to national wiring rules.
• Connect the equipment only to
a socket with a residual current
protection device (residual cur-
rent circuit breaker) with a rated
current of not more than 30
mA; minimum fuse 10 amperes.
• Before each use, check the
equipment, cable and plug for
damage. Defective cables are
not to be repaired, but rather
replaced by new ones. Have
any damage to your equipment
repaired by a specialist.
• If the power cable for this equip-
ment is damaged, it must be
replaced by the manufacturer,
a customer service agent of the
son in order to prevent hazards.
• Do not pull the plug from the
socket by the cable. Protect the
cable from heat, oil and sharp
edges.
ment by the cable.
• Use only extension cables that
are protected from spray water
and designed for outdoor use.
Always fully unroll a cable
drum before use. Check the ca-
ble for damage.
1 8
• Before any work on the equip-
ment, during work breaks and
in the case of non-use, remove
the plug from the socket.
• The cross-section of mains con-
nection lines must be no smaller
than rubber hose lines with
the designation H07RN-F. The
power cable wire cross section
must be at least 2.5 mm

Initial Operation

Mount carrying handle

Fix the carrying handle (7) to the
screws (8).

Setting up

If you would like to install the device,
screw it together with the base. A screw
connection with a fastening plate also
prevents the device from slipping.
By doing so, ensure a free access to
the drain screw (
Always put up the garden pump at a
-
point higher than the water surface
you wish to pump water from.
Where this is impossible, install a low
pressure-resistant shut-off implement
between the appliance and the suction
hose (available from specialist retailers).
-

Mains Connection

The pump you have purchases is already
tended for connection to an earthed socket
at 230 V~ / 50 Hz.
2
10).
-