3. Specifications / 4. Design and function
3. Specifications
Pressure limitation
GB
Model 23x.50/30, 26x.50/30, 23x.54:
Model 23x.36:
Temperature effect
When the temperature of the measuring system deviates from the
reference temperature (+20 °C): max. ±0.4 %/10 K of full scale value
IP Ingress protection
Enclosing case IP 65 (EN 60529/IEC 529)
For further specifications see WIKA data sheet PM 02.02, PM 02.04 or
PM 02.15 and the order documentation.
4. Design and function
Description
Nominal size 100 and 160 mm
The instruments measure the pressure by means of resilient
bourdon tube pressure elements
The measuring characteristics are in accordance with the EN 837-1
standard
10
Steady:
Fluctuating:
Short time:
Steady:
Fluctuating:
Short time:
WIKA operating instructions pressure gauge model 2 per ATEX
full scale value
0.9 x full scale value
1.3 x full scale value
end value of measuring range
0.9 x end value of measuring range
overload range