Herunterladen Inhalt Inhalt Diese Seite drucken

Commisioning Of The System - Bellcome SET VIDEOTÜRSPRECHANLAGE advanced Benutzerhandbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
5.1 Installation of the electromagnetic lock
Direct current (DC)
2 x 0.75 mm²
BUT
LC
LA/C
LA
Supply control unit
The Supply control unit can supply a current of
max. 1A for the supply of the lock.
The tension of +14 V DC is present on the LC
terminal of the Supply control unit.
The connection of a lock actuating button from the
interior of the building will be made at the BUT
and LC terminals of the Supply control unit.
5.2 Auxiliary command connection (optional)
6

COMMISIONING OF THE SYSTEM

6.1 Description of the supply control unit
The Supply control unit includes:
*PROG. : programming button
LED signaling of programming /
defect within the system
TIME:
Lock timing adjustment
*The kit does not require programming. This button is used only if you add additional Terminals or
panels to the system.
6.2 Checking the precision of the connections in the system and the
connection of the Supply control unit
Check the precision of the connections in the system!
The +14V , GND , CD , GNV and Uv signals are common to all components of the system.
The Vin and V out signals are specific to each Terminal or video camera (they are not to be
connected jointly).
Any short circuit between them leads to the non-operation of the entire system.
Cable
LC1
LC2
Direct current
electromagnetic lock (DC)
Relay contact
Maximum switched current: 1.5 A
(optional)
Alternative current (AC)
Transformer
230 V AC
12 V
BUT
LC
LA/C
LA
Supply control unit
Automation
S1: presence of tension at the
+14V - GND terminals
S2: existence of tension at the
+Uv - GND terminals
Protection lid for the
connections
Front lid
Protection lid for the
connections
AC
Cable
2 x 0.75 mm²
Alternative current
electromagnetic
lock (AC)
11/17

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis