Recycling and disposal
Both the ES 200
ES 200-2D and their packing mainly consist of
recyclable raw material.
The ES 200
and the respective accessories must not be
disposed of as domestic waste.
Please ensure that the old appliance and the
respective accessories (if available) are properly
disposed of.
Please abide by the prevailing national statutory provisions.
Safety during mounting
The working area has to be secured against
unauthorised access from other people. Falling items
or tools might cause injuries.
The ES 200
have to be secured against water and other liquids.
In any case, the way of mounting and the mounting
equipment, like for example screws and wall plugs,
have to be adequate with regard to the structural
conditions (steel structure, wood, concrete etc.).
The mounting of the ES 200
the ES 200-2D described herein are only an example.
Structural or local conditions, available tools or other
conditions might suggest a different approach.
Following the successful installation of the system, the
settings and the proper function of the ES 200
the ES 200 or the ES 200-2D and the safety
equipment have to be checked.
Only specially qualified staff may open the power
supply housing.
Disconnect the ES 200
ES 200-2D from power supply (de-energise the
system) before removing the cover of the power supply
housing. Remove mains plug or switch off fuse (with
permanent power supply).
Always pull at the plug and never at the cable when
unplugging the power supply.
Safety during commissioning
The protective earth conductor has to be connected.
The safety sensors are to be connected (see
commissioning instructions).
The operator and the active panels are properly linked.
The end stops are adjusted so that the sliding panels
meet the end stops when the system is adjusted to its
maximum opening width
Furthermore the sealing profiles of the active panels
and the passive panels must not collide while the door
is closed
Separately supplied components such as the program
switch, the EMERGENCY OFF pushbutton and
activators (radar motion detectors, NIGHT-/BANK key
switches) have to be mounted and connected.
Ensure that the door leaves run smoothly
The rechargeable battery pack has been installed
(optional).
Inspection and system approval
Before the first commissioning and depending on
requirements, however, at least once a year, the
, the ES 200 and the ES 200-2D have to be
ES 200
inspected by a properly qualified technician and serviced if
required.
A person trained by DORMA has to perform the inspection
and approve the system with the aid of the inspection book.
The respective results have to be documented in accordance
with DIN 18650-2 and the facility operator has to keep
these documents for at least one year.
We would recommend taking out a maintenance agreement
with DORMA.
ES 200
Easy
ES 200
ES 200-2D
, the ES 200, the
, the ES 200, the ES 200-2D
, the ES 200 and the ES 200-2D
, the ES 200 and
, the ES 200 or the
Briefing:
Following the adjustment, commissioning and functional
testing of the door system, the operating instructions have
to be handed over to the facility operator and a briefing has
to be made.
Behaviour of door system during varying weather conditions
The safety sensors (infrared light curtains) are designed to
safeguard the passage area. When it comes to adjusting the
sensitivity of the sensors, the protection of people always
has top priority. From time to time, changing climatic
conditions (such as rain or snow), flying leaves or direct
sunlight (reflected by certain floor finishes) may
accidentally trigger the sensors. As soon as the light
curtains have been triggered, the door may remain open for
up to one minute – as required by a certain standard. This is
only a standard procedure with the only purpose to protect
the users of the door system.Maintenance
The system has to be de-energised (disconnected from
power supply) before performing any kind of maintenance
work.
Remove the power plug or switch off the fuse (with
permanent power supply).
Care
The system has to be de-energised (disconnected from
power supply) before cleaning the system. Remove the
power plug or switch off the fuse (with permanent power
supply).
,
You may clean the ES 200
200-2D with a damp cloth and standard commercial
detergents.
You should not use scouring agents for cleaning purposes as
they might damage the surface finish.
Ensure that no water or other liquids drop on or into the
, the ES 200 or the ES 200-2D.
ES 200
Never stick metal objects into the openings of the
, the ES 200 or the ES 200-2D otherwise you
ES 200
might sustain an electric shock.
Wear
The following wear parts must be checked in regular
intervals and replaced if required in order to ensure the
smooth function of the unit.
Track rollers: every 2 years
Rubber end stops: at every service check
Track rail: every 5 years
Toothed belt: every 1,000,000 opening/closing
cycle
Floor guides: at every service check
Brushes (optional)
Only use original spare parts.