Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting - Mennekes AMTRON Compact Betriebs- Und Montageanleitung

Vorschau ausblenden Andere Handbücher für AMTRON Compact:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
T
T
ATTENTION
Material damage due to incorrect cleaning
Incorrect cleaning can cause damage to the housing or
components.
f Do not use running water and ensure that water can-
not reach live parts.
f Do not use high-pressure cleaning devices.
f Only use tools (e.g. brushes, cleaning agents) that are
suitable for plastic surfaces.
f Do not use aggressive cleaning agents or chemicals.
The device can be cleaned with a dry or damp cloth,
depending on application conditions and soiling. The
cleaning is carried out exclusively from the outside.
Procedure:
f First remove coarse dust and contamination with a
hand brush with soft bristles.
f If necessary, moisten a clean cloth that is suitable for
plastic surfaces with water and thoroughly wipe off the
device.
f Only clean the charging cable when it is unplugged.
20

9. Troubleshooting

If a fault occurs the "Fault" symbol lights up or flashes on
the LED information panel. The device cannot be used as
long as the fault has not been rectified.
Red LED flashing:
The fault can corrected by the user or operator.
Possible faults:
„ Maximum charging current exceeded
„ DC residual current
„ Overtemperature
To correct the fault, observe the following sequence:
f Terminate the charging process and disconnect the
charging cable.
f Wait approximately 20 seconds.
f Re-connect the charging cable and start the charging
process.
f If necessary, disconnect the charging cable and wait
until the device has cooled.
If the fault could not be corrected, contact your
responsible service partner.
Î "1.1 Service"
Red LED lights up:
The fault can only rectified by a qualified electrician.
The tasks described below may only be carried
out by a qualified electrician.
Possible Fault
Device configured
Check whether the blue rotary
incorrectly
encoder S3 is on position 8 or
9. These positions are not popu-
lated and trigger a fault.
Switching relays no
Device is defective and can only
longer turn off
be repaired by MENNEKES
Self test of the DC
Device is defective and can only
residual current
be repaired by MENNEKES
detection has failed
Possible Solution

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis