Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

CARBON FILTERS

The carbon filters are used when the hood is in filtering version. The carbon sets the air free
from kitchen odours. The carbon filters are to be found behind the grease filters and are
necessary if the hood is used in filtering version.
It is not necessary to use carbon filters, if the hood is used for suction use.
We have kinds of carbon filters: LONG LIFE Carbon filters that can be regenerated and
Standard Carbon Filters that cannot be regenerated.
LONG LIFE CARBON FILTERS
For carbon filter that can be regenerated you find an instruction with the filter.
The carbon filter that can be regenerated is marked with 230 °C on the frame.
INSTRUCTIONS: the carbon must be regenerated before the first use as the carbon, even if
special active carbon, takes on humidity. The humidity must be taken away.
Put the filter cassette on the grill of your oven and let is warm up for 1 hour at 230°C. Then
wait for 2 hours to let it become completely cold. If the filter is remounted before 2 hours the
hood can be damaged by remains of hot carbon. The process of regeneration can cause a
light change in the colour of the filter cassette. After this time the filter can be remounted in the
hood.
REGENERATION
Humidity and grease particules reduce the performances of air delivery and for this reason the
filter must be regenerated according to the time given in the instruction booklet.
Put the filter- cassette on the grill of your oven and let it warm up for 1 hour at 230°C. Then
wait for 2 hours to let it become completely cold. Only after this time the filter can be
remounted and your hood can work for other 4 months. If you use the hood in an intensive
way, the filter must be regenerated in shorter time. After 4 years the filter looses its
effectiveness and must be completely replaced (it is not possible to add special carbon).
STANDARD CARBON FILTERS (THAT CANNOT BE REGENERATED)
WARNING! WE RECOMMEND REPLACING CARBON FILTERS AFTER APPROX.
200-300 HOURS OF USE OF THE HOB. STANDARD CARBON FILTERS CANNOT
BE WASHED OR RE-CYCLED.
The manufacturer denies any responsibility for fires caused by failure in the
maintenance of carbon filters (replacing or regeneration of the carbon filters).
REPLACEMENT OF HALOGEN LAMPS
WARNING! Always replace the lamps with lamps which have the same electrical
characteristics. Before replacing the lamps, make sure that they are cold and that power has
been completely turned off.
Follow the instructions phases as shown in Figures of the L SERIES.
Connect back to electricity.
WARNING! If the lights are not working kindly check tha the lamps have been inserted in a
correct way.
LED LAMPS
To replace faulty Led Lamps always use an ELECTROLUX SERVICE CENTRE.
40

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis