Identify additional safety measures to protect the operator from the effects of noise and/or vibration, for
example: Maintaining the power tool and accessory tools, keeping the hands warm, organization of work
patterns.
Noise information
Sound power level (L
)
WA
Emission sound pressure level (L
Uncertainty for the sound pressure level (K
Total vibration
Surface grinding with the vibration-absorbing side handle (a
Uncertainty (K)
6 Operation
6.1 Preparations at the workplace
CAUTION
Risk of injury! Inadvertent starting of the product.
▶ Unplug the supply cord before making adjustments to the power tool or before changing
accessories.
Observe the safety instructions and warnings in this documentation and on the product.
6.2 Fitting the side handle
▶ Screw the side handle into one of the threaded bushings provided.
6.3 Fitting the guard
2
Note
The guard is keyed to ensure that ensure only guards of a type suitable for use with the power tool
can be fitted. The keyed locating lug also prevents the guard from coming into contact with the tool.
1. Release the clamping lever.
2. Fit the guard onto the arbor collar so that the keyed locating lug engages in the recess provided.
3. Turn the guard to the desired position.
4. Secure the guard by closing the clamping lever.
Note
The guard is preset to the correct clamping diameter by the adjusting screw. If the tension is too low
when the guard is fitted, the adjusting screw can be tightened slightly to increase the clamping force.

6.3.1 Adjusting the guard

1. Release the clamping lever.
2. Turn the guard to the required position.
3. Secure the guard by closing the clamping lever.
6.3.2 Removing the guard
1. Release the clamping lever.
2. Rotate the guard until the keyed locating lug is aligned with the keyed locating groove and then remove
the guard.
6.4 Accessory tools
CAUTION
Risk of injury. The accessory tool may be hot.
▶ Wear protective gloves when changing the accessory tool.
18
English
Printed: 27.07.2017 | Doc-Nr: PUB / 5238733 / 000 / 02
)
pA
)
pA
105 dB(A)
94 dB(A)
3 dB(A)
)
6.2 m/s²
h,AG
1.5 m/s²

Werbung