Fault / Cause / Remedy
Fault
Cause
Water not flowing
• Filter in solenoid valve blocked
• Solenoid valve defective
• Plug-in connector without contact
• Generator defective
• Storage electronic defective
• Battery (Emergency power supply) empty
Indicator lamp in the
• Generator defective and battery almost
sensor system flashes
empty (Fitting is supplied by emergency
power)
• Storage electronic defective and battery
almost empty (Fitting is supplied by
emergency power)
Indicator lamp in storage
• Plug-in connector without contact
electronic does not light
while the water flow
• Generator defective
Indicator lamp in storage
• Storage electronic defective
electronic flashes while
the water flow
Undesired water flow
• Sensor system detection zone set too high
for local conditions
• Automatic flushing activated
• Solenoid valve defective
Flow rate too low
• Mousseur dirty
• Filter in solenoid valve dirty
• Filter in connection hose dirty
Remedy
- Clean filter
- Replace solenoid valve
- Check 4 plug-in connectors
- Replace generator
- Replace storage electronic
- Replace battery housing
- Replace generator and battery housing
- Replace storage electronic and battery
housing
- Check plug-in connection between generator
and storage electronic
- Replace generator and battery housing
- Replace storage electronic and battery
housing
- Reduce range using remote control
(special accessory, Prod. No.: 36 407)
- Wait 1 - 10 minutes or deactivate automatic
flushing, see programme table
- Replace solenoid valve
- Clean or replace mousseur
- Clean filter
- Clean or replace filter