Installation

Flash through the supply pipes.
Install box depending on the building application. The
box can be mounted of the wall with the special support
frame, with the 10 mm studs for the wall to the desired
position, or in the traditional brickwall installation.
Watch the depth of installation.
Large differences in pressure between the hot and cold
water supply should be balanced.
The hot water connection must always be LHS and the
cold water connection RHS. The mixed water outlets in
the top and bottom of the housing can be used singly
or jointly as required. For single connection the outlet
not in use must be properly sealed with a screw plug.
Stop valve(s) must be provided to control
the flow of mixed water from the outlet(s).
After completion the whole installation must be flashed.
To do this replace the backflow preventers by special
flush plugs and open the isolation valves. Afterwords
check the pipes and connections for leakage.
Final installation
Finish sets ½"
Mondaro
Arco/Allegroh
1901
Carlton
Uno
Mondial
Metropol
Philippe Starck
Allegroh Novo
Steel
Azzur
Finish sets ¾"
Mondaro
Arco/Allegroh
1901
Carlton
Uno
Mondial
Metropol
Philippe Starck
Allegroh Novo
Steel
Azzur
18376
16376
19376
17376
13176
15376
14376
10376
36376
35376
34376
18378
16378
19378
17378
13178
15378
14378
10378
36378
35378
34378
GB
Initial use
After completition of the wall surface and installation of
the take off fittings, the front plate of the box must be
removed and the box has to be shortened to the front
edge of the tiles (seal with silicone.) When used in
hollow wall installation seal the edge to the gipsom
board. Put on sleeve and cover plate; mount setting
knob in position 38° and tighten screw.
Adjustment
Correction is necessary if the temperature measured at
the take off point differs from the temperature set on the
scale. To adjust temperature proceed as follows: Turn
the setting knob until water at a temperature of 38° C
comes out of the outlet. Loosen screw of setting knob.
Remove setting knob and turn to the 38° C position.
Attach setting knob again and tighten its screw.
Temperature limitation
The temperature range is limited by the safety check to
38° C. If a higher temperature is required, it is possible
to override the 38° C check by depressing the red safety
button.
Maintenance
Shut of hot and cold water supply.
Put setting knob to 38° C and hold in position.
Undo screw and pull off setting knob.
Remove sleeve and cover plate.
Unscrew thermoelement.
Unscrew N. R. valves, check and clean filters.
Check all components, clean, renew if necessary and
lubricate with special valve grease.
Re-assemble in reverse order.
Adjust unit.
Only original replacement parts may be used.
Important!
In the event of frost hazard and draining the pipes, the
isolation valves must be opened and the N. R. valves
must be removed.