Parts Replacement/Maintenance
Chart 1 – Air Caps
ORDER NO. FOR
NUMBER
AIR CAP
ON CAP
703540 (HVLP)
HV30
703538 (High Efficiency)
TE10
703539 (High Efficiency)
TE20
NOTE 1: Guns with HVLP caps must not exceed 0.7 bar (10 psi) air cap pressure
with gun fully triggered. (Aproximately 24 psi gun inlet pressure.) (See
accessories for air cap test kit which is available to set the exact cap
pressure.)
When used with the High Efficiency caps, this gun can be used
in unregulated areas and certain approved regulated areas. See
www.autorefinishdevilbiss.com for a complete listing of approved areas and
requirements for regulatory compliance. Gun inlet pressure may be adjusted
as required to any desired value in areas not requiring EPA compliance.
NOTE 2: When removing air cap from retaining ring, don't remove slip ring (2)
or retaining ring seal (5) from retaining ring. Damage to the parts may
occur. Slip ring and retaining ring seal are not available as replacements.
Simply wipe parts clean and reassemble with new or clean air cap.
Chart 2 – Fluid Nozzles & Fluid Needles
ORDER NO. FOR
NO. ON
FLUID NOZZLE
FLUID NOZZLE
703521
PRO-200-12
703522
PRO-200-13
703523
PRO-200-14
703589
PRO-200-15
NOTE: When replacing the fluid nozzle or fluid needle, replace both at the same time.
Lightly lubricate the threads of the fluid nozzle before reassembling. Torque
to 18–20 Nm (13–15 ft-lbs). Don't over tighten the fluid nozzle. Use 10 mm
wrench supplied with gun.
RECOMMENDED
AIR FLOW
INLET PRESSURE
LPM/SCFM
BAR/PSI
1.4 – 1.6 bar
411 – 467 LPM
20 – 24 psi
14.5 – 16.5 SCFM
1.4 – 2.4 bar
212 – 311 LPM
20 – 35 psi
7.5 – 11.0 SCFM
1.1 – 1.8 bar
255 – 340 LPM
16 – 26 psi
9 – 12 SCFM
TIP SIZE I.D.
NO. ON
(MM)
FLUID NEEDLE
1.2
PRO-301
1.3
PRO-301
1.4
PRO-301
1.5
PRO-301
ORDER NO. FOR
FLUID NEEDLE
703531
703531
703531
703531
TB-1008-C
11