COOLMATIC R series
Connecting to a battery
The refrigerator can be operated with a 12 V to 24 V DC voltage supply.
To avoid voltage loss and therefore a drop in performance, the
cable should be kept as short as possible and should not be inter-
rupted if this is possible.
For this reason avoid additional switches, plugs or power strips.
➤ Determine the required cross section of the cable in relation to the cable
length according to 0, page 6.
Key for 0, page 6
Co-ordinate axis
l
Caution
Make sure that the polarity is correct.
Before starting up the device for the first time, check whether the
operating voltage and the battery voltage correspond (see type plate).
➤ Connect the refrigerator
– As directly as possible to the pole of the battery or
– To a plug socket which is fused with at least 15 A (at 12 V) or 7.5 A (at
24 V).
Caution
Disconnect the cooling device and other power consuming
devices from the battery before connecting the battery to a quick
charging device.
Overvoltage can damage the electronics of the device.
For safety reasons the refrigerator is equipped with an electronic system to
prevent the polarity being reversed. This protects the refrigerator against re-
versed polarity when connecting to a battery and against short circuiting. To
protect the battery, the refrigerator switches off automatically if the voltage is
insufficient (see table below).
Switch-off voltage
Switch-on voltage
Setting up and connecting the refrigerator
Meaning
Cable length
Cable cross section
12 V (with TEC)
10,4 V (10,7 V)
11,7 V (13,0 V)
Unit
m
mm²
24 V (with TEC)
22,8 V (22,0 V)
24,2 V (26,0 V)