8. Connection

a) Voltage/current supply

The precise contact assignment can be found in chapter 7. The control module can be
operated either with 12 VDC, 24 VDC or 12 VAC. There are separate inputs available for this:
12 VDC
Terminal 1 = +12 VDC
Terminal 2 = GND
24 VDC
Terminal 3 = +24 VDC
Terminal 2 = GND
12 VAC
Terminal 1 = +12 VAC
Terminal 2 = 12 VAC
Never swap these connections, since the product will otherwise be damaged;
loss of warranty/guarantee!
The concurrent connection of several operating voltages (e.g. 12 VDC and
24 VDC) is not possible!
The product has a power intake of less than 50 mA in regular reading mode, and about
75 mA when switching the relay.
b) Relay Output
The relay output (terminals 4, 5, 6, see chapter 7) is potential-free. The connection data
of the relay can be found in the chapter on „Technical Data".
Never switch the mains voltage across the relay!