Herunterladen Inhalt Inhalt Diese Seite drucken

Zennio Z35 Benutzerhandbuch Seite 98

Kapazitives knx farb-touchpanel
Vorschau ausblenden Andere Handbücher für Z35:
Inhaltsverzeichnis

Werbung

724, 753, 782, 811
1 Bit
725, 754, 783, 812
1 Byte
726, 755, 784, 813
1 Byte
1 Bit
727, 756, 785, 814
1 Bit
728, 757, 786, 815
1 Bit
729, 758, 787, 816
1 Bit
730, 759, 788, 817
2 Bytes
731, 760, 789, 818
2 Bytes
732, 761, 790, 819
1 Bit
733, 762, 791, 820
1 Bit
734, 763, 792, 821
1 Bit
735, 764, 793, 822
1 Bit
736, 741, 746, 765,
770, 775, 794, 799,
1 Byte
804, 823, 828, 833
737, 742, 747, 766,
771, 776, 795, 800,
1 Byte
805, 824, 829, 834
738, 743, 748, 767,
772, 777, 796, 801,
1 Bit
806, 825, 830, 835
739, 744, 749, 768,
773, 778, 797, 802,
1 Bit
807, 826, 831, 836
740, 745, 750, 769,
774, 779, 798, 803,
1 Bit
808, 827, 832, 837
838
1 Byte
839, 877
2 Bytes
840, 878
2 Bytes
841, 879
2 Bytes
842, 880
1 Byte
http://www.zennio.com
O
C T R - -
DPT_Alarm
O
C T R - -
DPT_Scaling
O
C T R - -
DPT_HVACMode
O
C T R - -
DPT_Occupancy
O
C T R - -
DPT_Ack
I
C - - W -
DPT_Window_Door
I
C - - W -
DPT_Ack
I
C - - W -
DPT_TimePeriodSec
I
C - - W -
DPT_TimePeriodSec
I
C - - W -
DPT_Enable
I
C - - W -
DPT_DayNight
O
C T R - -
DPT_Occupancy
I
C - - W -
DPT_Ack
O
C T R - -
DPT_Scaling
O
C T R - -
DPT_HVACMode
O
C T R - -
DPT_Switch
I
C - - W -
DPT_Enable
I
C - - W -
DPT_Switch
I
C - - W -
DPT_SceneControl
I
C - - W -
DPT_Value_Temp
I
C - - W -
DPT_Value_Temp
O
C T R - -
DPT_Value_Temp
I
C - - W -
DPT_HVACMode
0/1
[Ix] Short Circuit Error
0% - 100%
[Ix] Presence State (Scaling)
1=Comfort
2=Standby
[Ix] Presence State (HVAC)
3=Economy
4=Building Gebäudeschutz
0/1
[Ix] Presence State (Binary)
0/1
[Ix] Presence: Slave Output
0/1
[Ix] Presence Trigger
0/1
[Ix] Presence: Slave Input
0 - 65535
[Ix] Presence: Wartezeit
0 - 65535
[Ix] Presence: Überwachungszeit
0/1
[Ix] Presence: Enable
0/1
[Ix] Presence: Day/Night
0/1
[Ix] Presence: Occupancy State
0/1
[Ix] External Motion Detection
0% - 100%
[Ix] [Cx] Detection State (Scaling) 0-100%
1=Comfort
2=Standby
[Ix] [Cx] Detection State (HVAC)
3=Economy
4=Building Gebäudeschutz
0/1
[Ix] [Cx] Detection State (Binary) Binary Value
0/1
[Ix] [Cx] Enable Channel
0/1
[Ix] [Cx] Force State
0-63; 128-191
[Thermostat] Scene Input
-273.00° - 670760.00°
[Tx] Temperature Source 1
-273.00° - 670760.00°
[Tx] Temperature Source 2
-273.00° - 670760.00°
[Tx] Effective Temperature
1=Comfort
[Tx] Special Mode
2=Standby
0 = No Error; 1 = Short Circuit
Error
0-100%
Auto, Comfort, Standby,
Economy, Building
Gebäudeschutz
Binary Value
1 = Motion Detected
Binary Value to Trigger the
Presence Detection
0 = Nothing; 1 = Detection from
slave device
0-65535 s.
1-65535 s.
According to parameters
According to parameters
0 = Not Occupied; 1 = Occupied
0 = Nothing; 1 = Motion
detected by an external sensor
Auto, Comfort, Standby,
Economy, Building
Gebäudeschutz
According to parameters
0 = No Detection; 1 = Detection
Scene Value
External Sensor Temperature
External Sensor Temperature
Effective Control Temperature
1-byte HVAC Mode
Techn. Support:
http://support.zennio.com
Z35
98

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis