Adjustment Procedures - Grundig KM 12 Serviceanleitung

Inhaltsverzeichnis

Werbung

KM 12

Adjustment Procedures

GB
1. Tuner
Test equipment: Test Generator, Stereo Coder, Oscilloscope, DC Voltmeter, AF Voltmeter
Adjustment
1. AM IF
MW; set the tuner to 522kHz.
Test generator 450kHz at aerial input.
U
as low as possible; f
a
AF voltmeter at test point TP1(IF).
2. AM Oscillator
MW;
DC voltmeter at test point TP1(VT).
3. AM Aerial
MW;
Bandpass
Test generator at aerial input.
U
as low as possible; f
a
AF voltmeter at loudspeaker output.
4. FM Oscillator
FM;
DC voltmeter at test point TP1(VT).
5. FM Aerial
FM;
Bandpass
Test generator at aerial input.
U
as low as possible; f
a
AF voltmeter at loudspeaker output.
6. Stereo
FM;
Stereo coder 98MHz at aerial input.
U
= 26dBµV; f
a
2. Cassette Part
Test equipment: AF Voltmeter, Frequency Counter, Test Cassette 449 Part No.: 35079-019.00
Adjustment
1. Azimuth
Access to the screws is gained through holes below the
cassette flaps.
Play Test Cassette 449, 10kHz part.
AF voltmeter at AF output.
2. Tape Speed
Tape, Fe.
Play Test Cassette 449, 3150Hz part.
Frequency counter at AF output.
3. CD Part
Test equipment: DC Voltmeter, Oscilloscope, Test CD Part No.: 72008-376.00
Adjustment
1. RF Gain
Set CD player to STOP.
DC voltmeter at test point CN12.
2. E-F-Balance
Connect a diode (1N4148) between pin 19 (anode) and
pin 8 (cathode) of connector CN601 on the Front Panel
as shown on page 3 - 12, and solder the buttons
„CD CHECK" and „REPEAT" on to the panel.
Oscilloscope to test point CN02 (+/-).
Load the test CD and play.
Depress the soldered buttons „CD CHECK" and
„REPEAT" simultaneously and adjust VR02.
On completion of this adjustment press the „STOP"
button and remove the diode.
GRUNDIG Service
Preperation
= 400Hz; m = 30%;
mod
= 400Hz; m = 30%;
mod
= 400Hz; ∆f = 22.5kHz;
mod
= 19kHz;
mod
Preperation
Preperation
Abgleichvorschriften / Adjustment Procedures
Adjustment Procedure
Adjust T102 for AF maximum.
Adjust L105 at 522kHz for 1.2V
±
Check at 1629kHz 8.0V
1.0V.
Adjust alternately L104 at 603kHz and TC102 at
1404kHz for AF maximum.
Adjust L103 at 87.5MHz for 1.2V.
±
Check at 108MHz 8.0V
1.0V.
Adjust alternately L102 at 90.0MHz and TC101 at
106.0MHz for AF maximum.
With SFR101 adjust the stereo threshold (U
so that the stereo indication still illuminates on the
display.
Adjustment Procedure
A
Adjust screw
for AF maximum.
Adjust SFR201 for 3110Hz - 3240Hz.
Adjustment Procedure
±
Adjust VR01 for 0V
20mV.
Set VR02 so that the signal amplitude is symmetrical
to the datum line (A=B).
±
0.05V.
= 26dBµV)
a
A
2 - 2