Automatic Logging
RD8000 logging and GPS locator models offer a powerful data logging system which
records all the instrument's critical parameters (including GPS position, if available) and
warnings in its internal memory at the rate of 1/sec.
The automatic logging system is always active and cannot be disabled. Its memory is
capable of storing at least 1 year's worth of normal usage data – based on 4 hours
operation per day, 5 days per week, 20 days per month.
Logs can be retrieved using the RD Manager PC application for usage analysis and
survey validation. Refer to its operation manual for further information.
GPS
The RD8000 locator can be paired to an external GPS module or use its internal GPS
module (GPS models only) to be able to detect and store its latitude, longitude and
accurate UTC time alongside its location data using SurveyCERT or the automatic
logging system (GPS and logging models only).
The presence of GPS data allows for the data to be mapped easily and to export and
save the information directly into GIS systems.
GPS menu
To enter the GPS menu:
1.
Press the
key to enter the menu.
2.
Scroll to the GPS menu using the
3.
Press the
key to enter the GPS menu.
There are 5 options:
RESET: Select YES to reset the internal GPS (GPS models only).
INT: Select this to use the internal GPS if present.
EXT: Select this to use the GPS from a compatible paired device.
OFF: Select this to switch off the internal GPS module and save battery.
SBAS: Set SBAS (Satellite-based augmentation systems) mode to improve
GPS accuracy (North America only). When ON the GPS system will take
longer to lock.
4.
Press the
key to accept your changes and exit the GPS menu.
5.
Press the
key to exit the menu.