Herunterladen Diese Seite drucken

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Assembly
The fitting must installed, flushed and
tested after the valid norms!
1. Flush through the supply pipes.
2. Place the mixer including the sealing washer
in position on the sink.
3. Slip the plastic washer, the slide washer, the
metall washer and collar nut over the hose
and threaded base and tighten the collar nut
by hand. If there is not enough space, please
use only the slide washer and the metall with-
out the plastic washer.
4. Tighten screws.
5. Connect the connecting hose to the angle
valves;
cold right - hot left.
Large differences in pressure between the hot
and cold water supply should be balanced.
Technical Data
Operating pressure:
Recommended operating pressure: 1 - 5 bars
Test pressure:
Hot water temperature:
Recommended hot water temp.: 65° C
Rate of flow:
Hansgrohe single lever mixers can be used
together with hydraulically and thermically con-
trolled continuous flow heaters if the flow pres-
sure is at least 1.5 bars.
To adjust the hot water limiter on single lever mix-
ers, please see page 13.
No adjustment is necessary when using a contin-
uous flow water heater.
6
English
max. 10 bars
16 bars
max. 80° C
13 l/min 3 bars

Spare parts

1
handle
1.1 screw cover
2
flange
3
nut
4
cartridge, assy
5
locking screw
6
aerator cpl.
7
spout
8
sealing set
9
fixation set
10
connetion hose 600 mm
XXX = Colors
000 chrome plated
090 chrome plated/gold plated
750 alux
96652XXX
96338000
94192XXX
94194000
92730000
96059000
96653XXX
96654XXX
92646XXX
95049000
14099XXX

Werbung

loading