9. Specifications
Models DPGT43HP.100, DPGT43HP.160
Pressure limitation
Steady
Fluctuating
Overload safety and
EN
max. working pressure
Temperature effect
Wetted materials
Media chamber with process
connection, venting of the media
chambers, bellows
Pressure element
Non-wetted materials
System fill fluid measuring cell
Case, movement, bayonet ring
Dial
Pointer
Window
Ingress protection per IEC/EN 60529 IP54; option: IP65
For further specifications see data sheet PV 17.13
32
Full scale value
0.9 x full scale value
Either side max. 40, 100, 250 or 400 bar
When the temperature of the measuring system deviates from
the reference temperature (+20 °C): max. ±0.5 %/10 K of full
scale value
Stainless steel 316Ti (1.4571)
≤ 0.25 bar: Stainless steel 316L
> 0.25 bar: Stainless steel 316L/Inconel
Silicone oil
Stainless steel
Aluminium, white, black lettering
Aluminium, black
Laminated safety glass