8 ) E L E C T R I C A L C O N N E C T I O N
The electrical connections of the appliance
must be carried out in compliance with the
provisions and standards in force.
- Before connecting the appliance, check that the
socket or system has an efficient earth connection
in compliance with the provisions and standards in
force. The manufacturer declines all responsibility
for failing to comply with these provisions.
When the appliance is connected to the
electricity main by a socket:
- fit a standard plug "C" suited to the load indicated
on the data label to the cable. Fit the wires
following figure 11, taking care of respecting the
following correspondences:
letter L (live) = brown wire;
letter N (neutral) = blue wire;
earth symbol
= green - yellow wire.
- The power supply cable must be positioned so
that no part of it is able to reach an
overtemperature of 65 K.
- Never use reductions, adapters of shunts for
connection since these could create false contacts
and lead to dangerous overheating.
INSTALLATION
When the appliance is connected straight to the
electricity main:
- install an omnipolar circuit-breaker between the
appliance and the electricity main. This circuit-
breaker should be sized according to the load
rating of the appliance and possess a minimum 3
mm gap between its contacts.
- Remember that the earth wire must not be
interrupted by the circuit-breaker.
- Alternatively, the electrical connection may also be
protected by a high sensitivity differential circuit-
breaker.
You are strongly advised to fix the relative yellow-
green earth wire to an efficient earthing system.
WARNINGS:
all our appliances are designed and
manufactured in compliance with European
standards EN 60 335-1 and EN 60 335-2-6 plus
the relative amendments.
The appliance complies with the provisions of
the following EEC Directives:
- 89/336 + 92/31 + 93/68 regarding to
electromagnetic compatibility.
- 73/23 + 93/68 regarding electrical safety.