Herunterladen Inhalt Inhalt Diese Seite drucken

Hameg HM400 Handbuch Seite 33

Analog-oszilloskop
Vorschau ausblenden Andere Handbücher für HM400:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

34
HOLD OFF/ON (LED button)
By pressing this button a hold-off time can be selected, the
amount of hold-off can be adjusted with the knob TIME/DIV.
35
Z – INP (LED button)
Activates the external Z axis input
as indicated by the LED.
36
INPUT CH 1 (BNC connector)
Signal input for channel 1 (CH 1), in XY mode this input will
control the horizontal movement (X) of the trace.
37
INPUT CH 2 (BNC connector)
Signal input for channel 2 (CH 2), in XY mode this input will
control the vertical trace (Y) movement.
38
PROBE ADJUST (contact)
1 KHz/1 MHz square wave output for the adjustment of probes
other than 1:1.
39
PROBE ADJUST (contact)
Ground connection for the probe adjustment.
40
EXT. TRIG/Z-INP (BNC connector)
Input for external trigger or intensity modulation signals.
41
CH 1 (Mode select button with LED)
Activates the channel 1 (CH 1) input or selects access to the
settings memory 1 as indicated by the LED.
42
CH 2 (Mode select button with LED)
Activates the channel 2 (CH 2) input or selects access to the
settings memory 2 as indicated by the LED.
POWER
46
45
44
43
42
41
POWER
POWER
CH1
CH1
CH2
CH2
DUAL
DUAL
ADD
ADD
COMP
COMP
±10 V
COMP .
pp
∼ 50 Hz
TESTER
47
20
40
for intensity modulation
4
6
2
3
5
7
POWER
ADJUST
SELECT
INTENS
+ +
FOCUS
TRACE
1
8
9
10
ADJUST
SELECT
!
INTENS
+
+
FOCUS
TRACE
SAVE
push long
RECALL
POSITION 1
POSITION 2
1
1–6
AUTOSET
2
VOLTS / DIV
VOLTS / DIV
.2
.1
.2
.5
.5
3
50
VAR
20
1
1
10
2
2
5
5
5
2
5
10
10
XY
XY
1
20
20
V
mV
V
6
DC
DC
AC
GND
AC
GND
CH 1
CH 2
X-INP
INPUTS
1 MΩ II 15 pF
max.
400 V
p
!
CAT I
18 29
36 30
19 31
37
32
O v e r v i e w o f t h e c o n t r o l s
43
42
DUAL (Mode select button with LED)
Selects dual channel operation or access to the settings me-
.
mory 3 as indicated by the LED.
44
42
ADD (Mode select button with LED)
Selects the add mode of the vertical amplifi er or access to the
settings memory 4 as indicated by the LED.
45
42
XY (Mode select button with LED)
Selects the XY mode or access to the settings memory 5 as
indicated by the LED.
46
42
COMP (Mode select button with LED)
Activates the COMPONENT tester or selects access to the
settings memory 6 as indicated by the LED.
47
42
COMPONENT TESTER (two 4 mm test jacks)
Terminals of the component tester, the left one is connected to
the chassis and thus to the safety earth connector of the mains
cable.
42
43
43
43
12
13 14
15
16
17
11
HM400
40 MHz ANALOG OSCILLOSCOPE
AUTO
TRIGGER
TRIG'd
X-POSITION
LEVEL
NORM
SLOPE
X-MAG
x10
TIME / DIV
.2
.1
.1
TRIGGER
ms
.5
50
1
20
CH 1
AC
2
10
5
CH 2
DC
10
5
20
2
LINE
LF
50
1
.1s
mV
.2s
.1
EXT
TV
HOLD
OFF
INV
ON
Z-INP
EXT. TRIG / Z-INP
PROBE ADJUST
1 kHz / 1 MHz
ca. 0.2 Vpp
39
38
40
33
34
TRIGGER
CH 1
50
VAR
CH 2
20
10
5
LINE
2
1
.5
µs
.2
EXT
1 MΩ II
15 pF
max.
100 V
p
21
22
23
24
20
35
Subject to change without notice
43
43
43
43
43
AC
DC
LF
TV
26
28
27
25
31

Quicklinks ausblenden:

Werbung

Kapitel

Inhaltsverzeichnis
loading