Personnel authorized to carry out repairs

Authorization to carry out repairs depends on the measuring device' s approval type. The table below shows the authorized group
of people in each case.
Whoever carries out the repairs has full responsibility to ensure that work is carried out safely and to the required quality
standard. He/she must also guarantee the safety of the device following repair.
Measuring device approval
Without approval
With approval (e.g. IECEx)
1)
1 = Qualified specialist on customer side, 2 = Service technician authorized by Endress+Hauser, 3 = Endress+Hauser (return measuring
device to manufacturer)

Safety instructions

• Check whether the spare part matches the labeling on the
measuring device as described on the cover page.
• The spare part sets and Installation Instructions are used to
replace a faulty unit with a functioning unit of the same
type.
Only use original parts from Endress+Hauser.
• Comply with national regulations governing mounting,
electrical installation, commissioning, maintenance and
repair procedures.
• The following requirements must be met with regard to
specialized technical staff for the mounting, electrical
installation, commissioning, maintenance and repair of the
measuring devices:
– Specialized technical staff must be trained in instrument
safety.
– They must be familiar with the individual operating
conditions of the devices.
– In the case of Ex-certified measuring devices, they must
also be trained in explosion protection.
• The measuring device is energized! Risk of fatal injury from
electric shock. Open the measuring device only when the
device is de-energized.
• When using Ex-certified measuring devices: Open device
only when in a de-energized state (allow 10 minutes to
elapse after switching off the power supply) or in
environments which do not have a potentially explosive
atmosphere.
• In the case of measuring devices in safety-related
applications in accordance with IEC 61508 or IEC 61511:
Commission in accordance with Operating Instructions after
repair. Document the repair procedure.
• Before removing the device: set the process to a safe state
and purge the pipe of dangerous process substances.
• Hot surfaces! Risk of injury! Before commencing work: allow
the system and measuring device to cool down to a
touchable temperature.
Additional safety instructions for PMD75 with small measuring ranges (10 mbar, 30 mbar) and a
glass cover
For reasons of electromagnetic compatibility (EMC), the original glass cover must be replaced on measuring devices with a
new 10 mbar or 30 mbar sensor. The need to replace the cover is checked at the factory. If a new coated glass cover is
supplied with the delivery, this cover must be used.
2
Authorized repair personnel
1, 2, 3
1, 2, 3
• In the case of devices in custody transfer, the custody
transfer status no longer applies once the seal has been
removed.
• The Operating Instructions for the device must be followed.
• Risk of damaging the electronic components! Ensure you
have a working environment protected from electrostatic
discharge.
• After removing the electronics compartment cover: risk of
electrical shock due to missing touch protection!
Turn the measuring device off before removing internal
covers.
• Modifications to the measuring device are not permitted.
• Only open the housing for a brief period. Avoid the
penetration of foreign bodies, moisture or contaminants.
• Replace defective seals only with original seals from
Endress+Hauser.
• If threads are damaged or defective, the measuring device
must be repaired.
• Threads (e.g. of the electronics compartment cover and
connection compartment cover) must be lubricated if an
abrasion-proof dry lubricant is not available. Use acid-free,
non-hardening lubricant.
• If spacing is reduced or the dielectric strength of the
measuring device cannot be guaranteed during repair work,
perform a test on completion of the work (e.g. high-voltage
test in accordance with the manufacturer' s instructions).
• Service plug:
– Do not connect in explosive atmospheres.
– Only connect to Endress+Hauser service devices.
• Observe the instructions for transporting and returning the
device outlined in the Operating Instructions.
If you have any questions, please contact your
Endress+Hauser service
1)
organization.