11.

Remedy of faults

Pos: 147 /Filter/FiltoMatic CWS/Störungstabelle_FiltoMatic_CWS neu @ 9\mod_1229421115179_121.doc @ 58743
Malfunction
The controller does not switch on
Water from the DN70 outlet does not return
to the pond
Dirty water pump does not switch on
UVC lamp does not switch on
Pos: 148 /Alle Produkte/Dummy_module/Abstand 18 pt @ 6\mod_1196355593257_0.doc @ 41089
Pos: 149 /Alle Produkte/Überschriften/H1 Verschleißteile @ 8\mod_1223247075102_121.doc @ 53883
12.

Wear parts

Pos: 150 /Filter/FiltoMatic CWS/Verschleissteile_FiltoMatic_CWS @ 9\mod_1227866026421_121.doc @ 57550
Wear part
UVC lamp
Quartz glass tube
Cleaning rotor
Foam filter
Pos: 151 /Alle Produkte/Dummy_module/Abstand 18 pt @ 6\mod_1196355593257_0.doc @ 41089
Pos: 152 /Alle Produkte/Überschriften/H1 Entsorgung @ 7\mod_1196625583904_121.doc @ 41547
13.

Disposal

Pos: 153 /Alle Produkte/Entsorgung - gem. Bestimmungen @ 8\mod_1223247321369_121.doc @ 53910
Dispose of the unit in accordance with the national legal regulations.
Pos: 154 /Alle Produkte/Dummy_module/===== Seitenwechsel ===== @ 0\mod_1125648978015_0.doc @ 1630
30
Cause
No mains voltage
Controller incorrectly positioned on the UVC
clarifying unit
Aquamax pump not switched on
Stop valve closed with the lid open
Pump rotor blocked
Temperature < 5 °C
Container already empty
Container partly emptied, dirty water pump
cannot prime
UVC lamp defective
The safety system in the UVC clarifying unit
has tripped as a result of overvoltage in the
mains
Model
FiltoMatic 3000 CWS
FiltoMatic 6000 CWS
FiltoMatic 12000 CWS
FiltoMatic 3000 CWS
FiltoMatic 6000 CWS
FiltoMatic 12000 CWS
FiltoMatic 3000 CWS
FiltoMatic 6000 CWS
FiltoMatic 12000 CWS
FiltoMatic 3000/6000/12000 CWS
Remedy
Check mains voltage
Check supply lines
Check the controller seating
Switch on Aquamax pump
Open stop valve
Clean pump rotor
Unit cannot be operated
Fill container
Fill container
Changing the UVC lamp
Switch of the rated voltage and on again to
reset the safety system
Check that the UVC lamp is lit in the
control window (blue light)
To test, we suggest to switch on the UVC
lamp using the UVC key (operating status
ON)
Ident No.
56112
56236
56237
22622
29419
11440
12703
12704
12705
50314