3. Technical data

3.1 Operating conditions

The resistance of the parts that come into contact
with media depends on the medium, media
temperature and operating pressure.
Caution
Ensure that parts in contact with the media are
chemically resistant to the dosing medium under
operating conditions.
3.1.1 Dosing tank
Min. /Max. storage temperature: -20 °C to +50 °C
Min. /Max. ambient temperature: -20 °C to +45 °C
Min. /Max. liquid temperature: -20 °C to +45 °C
– Dosing medium must be in the liquid phase.
Thin (max. 200 mPas), non-explosive dosing media without
abrasive or long-fibre components. The dosing medium must not
chemically attack the materials of the DTS dosing tank station.
3.1.2 Components
For the below mentioned operating conditions, refer
to the installation and operating instructions of the
Note
components used.
Min. /Max. storage temperature
Min. /Max. ambient temperature
Min. /Max. liquid temperature
Max. relative humidity (non-condensing)
Max. altitude above sea level

3.2 Electrical data

Electric stirrer for tanks of 60 l and 100 l
– single-phase, 220-240 V, 50/60 Hz
Electric stirrer for tanks of 200 l, 300 l, 500 l and 1000 l
– single-phase, 230 V, 50 Hz (standard),
or
– single-phase, 240 V, 50 Hz
For more details, refer to the installation and operating
instructions for the electric stirrer and dosing pump.

3.3 Hydraulic data

3.3.1 Process connection
with injection unit: G 1/2
without injection unit: see hydraulic connection of the dosing
pump
3.3.2 Suction line
Suction hose PE 6/9 mm (9/12 mm for DDI 60-10) with included
connection for the suction side of the dosing pump.

3.4 Dimensions

460
Fig. 2
Dosing tank station 60 / 100 l
Pump type
DDA 7.5-16, DDC 6-10, DDC 9-7
DDE 6-10
DDA 12-10, DDA 17-7, DDC 15-4
DDE 15-4
DDA 30-4
DMX 221, p
= 3 bar
max.
DMX 221, p
= 4 bar
max.
DMX 221, p
= 10 / 16 bar
max.
DDI 60-10
* A: height of pump up to discharge connection
** B: height of pump housing or motor
188
A*
B**
[mm]
[mm]
196
200.8
196
161.5
200.5
200.8
200.5
161.5
204.5
200.8
197
319
192
319
179
319
252
230
7