PROGRAMMING

Operating media may leak.
These:
• are hazardous to water,
• are category 1,2 and 3 inflammable liquids,
• can ignite and cause burning,
• may cause falling injuries due to slipping.
Enter these values with care!
The entry values are also retained in the event of the failure of the supply voltage.
Menu
0.Exit
1.Probe
2.Liquid
If the density of the stored medium is unknown, the reference height can be entered in menu
item "10.Trim height"
part no. 28 100 57 f
Overfilling of the tank due to incorrect entry values.
Input function
Press [ENTER] to return to display mode
Select probe measuring range see type label of the
probe - default setting 250 mbar
Standard probe
100mbar
150mbar
160mbar
200mbar
250mbar
400mbar
500mbar
1.000mbar
2.000mbar
3.000mbar
5.000mbar
Set mbar
Select the medium
Medium
Fuel oil
Water
Diesel
Biodiesel
RME, FAME
Rape oil
Palm oil
Motor oil
AdBlue
Regular
petrol
Premium
petrol
Density value
®
SmartBox
1 / SmartBox
max. tank height for
fuel oil
1.20 m
1.80 m
1.90 m
2.40 m
2.90 m
4.70 m
6.00 m
12.00 m
24.00 m
36.00 m
60.00 m
Density value kg/m³ (15 °C)
845 kg/m³ - default setting
999 kg/m³
830 kg/m³
880 kg/m³
880 kg/m³
915 kg/m³
910 kg/m³
865 kg/m³
1090 kg/m³
743 kg/m³
750 kg/m³
Enter a special density value
with different measuring range
®
2 / SmartBox
Input value
________mbar
water
1.00 m
1.50 m
1.60 m
2.00 m
2.50 m
4.00 m
5.00 m
10.00 m
20.00 m
30.00 m
50.00 m
_______kg/m³
®