5.
Expanding the main-memo-
ry capacity
5.1

Scope of delivery

Abb. 13: Scope of delivery, retrofit kit 1 688 400 611
1 Memory module (RAM)
2 Safety bracket
3 Fastening screw (2)
4 Heat conducting pad
5.2
Compatibility
RAM
DCU 220 G1
1 688 400 611
8GB DDR4 2133 MHz
5.3
Installing main memory
!
The installation should be done in switched off con-
dition with the batteries removed.
1. Remove the 8 screws of the cover.
2. Lift the cover at the contact point and remove from
above.
Robert Bosch GmbH
3. Mount the heat conducting pad on the metal plate.
4. Place the RAM into the plug-in connector at an angle
of 30°.
DCU 220 G3
1 687 023 800 -
... 805
5. Press the protruding end of the RAM down until the
RAM engages with the metal clamps.
6. Mount the safety bracket using the 2 screws provi-
ded.
7. Place the cover and mount it with 8 screws.
| DCU 220 | 11
de
|
1 689 975 287
2017-07-06

Werbung

Inhaltsverzeichnis
loading